Rating/ Performance
1.Rating
Types of load | Resistive load (cosø≒1) | Inductive load (cosø≒0.4) | Motor or lamp load |
---|
N.C. contact | N.O. contact |
---|
125V AC | 15A | 10A | 4A | 2A |
---|
250V AC | 15A | 10A | 3A | 1.5A |
---|
125V DC | 0.5A | 0.05A | - | - |
---|
2.Characteristics
Contact arrangement | 1 Form C |
---|
Initial contact resistance, max. | 15mΩ (By voltage drop 6 to 8V DC 1A) |
---|
Initial insulation resistance (At 500V DC) | Min. 100MΩ |
---|
Initial breakdown voltage | 1,000Vrms for 1 min Between non-consective terminals 1,500Vrms for 1 min Between dead metal parts and each terminal 1,500Vrms for 1 min Between ground and each terminal |
---|
Expected life (Min. operations) | Mechanical | 106 (at 60 cpm) |
---|
Electrical | 105 (at 60 cpm) |
---|
3.Operating characteristics
特性 | O.F.(N{gf}) max. | R.F.(N{gf}) min. | P.T. max. | M.D. max. | O.T.(mm) min. |
---|
Push plunger | 9.80{1,000} | 2.16{220} | 2.0 .079 | 0.1 .004 | 5.0 .197 |
---|
Roller plunger | 3.43{350} | 1.12{114} | 0.5 .020 | 0.1 .004 | 3.6 .142 |
---|
Cross roller plunger | 3.43{350} | 1.12{114} | 0.5 .020 | 0.1 .004 | 3.6 .142 |
---|
Roller lever | 6.67{680} | 1.67{170} | 4.5 .177 | 0.4 .016 | 5.5 .217 |
---|
4.Protective characteristics
Protective construction | Slitted type limit switches |
---|
IEC |
---|
IP60 | ○ * |
---|
IP64 | ○ * |
---|
*Except AZ6102,6202,AZ6103,AZ6203