Basic Information
Linear and Direct Drive (DD) Motor Control Drive
High precision and high speed advancement of linear and DD Control Drive
Download
Basic Information
Lineup
System Configuration
Linear and Direct Drive (DD) Motor Control Drive
High precision and high speed advancement of linear and DD Control Drive

※1 Type SM
※2 Type SL
Contact Us
| Power supply | Servo driver part number*1 | Applicable motor rated output*2 | |||
|---|---|---|---|---|---|
| Rated current A (rms) | Max. Current A (rms) | ||||
| Carrier frequency | |||||
| 6 kHz | 8 kHz | 12 kHz | |||
| Single Phase AC100 V to 120 V | MADL □ 01 △△ | - | - | 1.2 | 3.7 |
MADL □ 11 △△ | - | - | 1.6 | 5.5 | |
MBDL □ 21 △△ | 2.5 | 2.1 | - | 7.4 | |
MCDL □ 31 △△ | 4.6 | 4.1 | - | 14.3 | |
| Single /Three Phase AC200 V to 240 V | MADL □ 05 △△ | - | - | 1.2 | 3.8 |
MADL □ 15 △△ | - | - | 1.6 | 4.8 | |
MBDL □ 25 △△ | 2.6 | 2.1 | - | 7.3 | |
MCDL □ 35 △△ *3 | 4.1 | - | - | 13.2 | |
MDDL □ 45 △△ *3 | 5.9 | - | - | 15.5 | |
MDDL □ 55 △△ *3 | 9.4 | - | - | 26.1 | |
| Three Phase AC200 V to 240 V | MEDL □ 83 △△ *3 | 13.4 | - | - | 37.4 |
MEDL □ 93 △△ *3 | 17.0 | - | - | 48.0 | |
MFDL □ A3 △△ *3 | 18.7 | - | - | 54.4 | |
MFDL □ B3 △△ *3 | 33.0 | - | - | 72.1 | |
MGDL T C3 △△ | 40.0 | - | - | 116.6 | |
MHDL T E3 △△ | - | 66.1 | - | 167.2 | |
MHDL T F3 △△ | 80.2 | - | - | 207.9 | |
| Three Phase AC400 V | MDDL T 44 △△ | 1.5 | 1.2 | 0.8 | 4.5 |
MDDL T 54 △△ | 2.9 | - | - | 8.7 | |
MDDL T 64 △△ | 4.7 | - | - | 14.1 | |
MEDL T 84 △△ | 6.7 | - | - | 19.7 | |
MFDL T A4 △△ | 9.4 | - | - | 28.2 | |
MFDL T B4 △△ | 16.5 | - | - | 42.4 | |
MGDL T C4 △△ | 20.3 | - | - | 58.7 | |
MHDL T E4 △△ | - | 32.3 | - | 83.7 | |
MHDL T F4 △△ | 40.1 | - | - | 103.9 | |
*1: Please refer to “□” and “△△” as per below ;
□Common
N : Without Safety
T : With Safety STO
△△ A6L
SM : Full Version
SL : Only Pulse control
△△ A6NL
NM : Multi-function type
NL : Standard type
△△ A6BL
BM : Multi-function type
BL : Standard type
There are restrictions on combinations. Multifunction type (M suffix is M) has safety function (T in the 5th digit of model number), Position control type, standard type (L at the end of the model number) No safety function (5th digit in the model number is N).
*2: Select and use a motor whose rated current and maximum current do not exceed the values specified.
*3: For AC 200–240 V models in frame sizes C, D, E, and F, adding ‘0C0’ to the end of the part number converts it to the type that supports BiSS‑C.
Part Number Example: MCDL□35B△0C0



*: This photo shows multi-functional type. Standard type does not have X3 and X5 connectors.
MENU
Relays, Couplers, Connectors, Switches, and Other
Control Components & Electronic Device Products
FA Sensors, PLC ,Eco Power Meters, Times, Counters, Limit Swicheds and Other FA Sensors & Components
Contact UsMotors for FA & Industrial Application, Motors for Appliance & Automotive
Contact Us