{lead}
{name}
  • {name}
  • 日本語
  • English (Global)
  • English (Asia Pacific)
  • 简体中文
  • 繁體中文
  • 한국어
Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

MINAS A6L Series Servo Driver (Special Order Products)

  • Basic Information

  • Lineup

  • System Configuration

Basic Information

pic01

Linear and Direct Drive (DD) Motor Control Drive
High precision and high speed advancement of linear and DD Control Drive

  • copy_of_ce_emc
  • ukca
  • ul_cul
  • ul_c_us_listed
  • tuv_functional_safty
  • standard-note01
  • tuv_tested
  • standard-note02
  • of_kc
  • ※1 Type SM
    ※2 Type SL

Lineup

Drive list

Power supplyServo driver part number*1Applicable motor rated output*2
Rated current A (rms)Max.
Current
A (rms)
Carrier frequency
6 kHz8 kHz12 kHz
Single Phase
AC100 V to 120 V
MADL □ 01 △△
-
-
1.2
3.7
MADL □ 11 △△
-
-
1.6
5.5
MBDL □ 21 △△
2.5
2.1
-
7.4
MCDL □ 31 △△
4.6
4.1
-
14.3
Single /Three Phase
AC200 V to 240 V
MADL □ 05 △△
-
-
1.2
3.8
MADL □ 15 △△
-
-
1.6
4.8
MBDL □ 25 △△
2.6
2.1
-
7.3
MCDL □ 35 △△ *3
4.1
-
-
13.2
MDDL □ 45 △△ *3
5.9
-
-
15.5
MDDL □ 55 △△ *3
9.4
-
-
26.1
Three Phase
AC200 V to 240 V
MEDL □ 83 △△ *3
13.4
-
-
37.4
MEDL □ 93 △△ *3
17.0
-
-
48.0
MFDL □ A3 △△ *3
18.7
-
-
54.4
MFDL □ B3 △△ *3
33.0
-
-
72.1
MGDL T C3 △△
40.0
-
-
116.6
MHDL T E3 △△
-
66.1
-
167.2
MHDL T F3 △△
80.2
-
-
207.9
Three Phase
AC400 V
MDDL T 44 △△
1.5
1.2
0.8
4.5
MDDL T 54 △△
2.9
-
-
8.7
MDDL T 64 △△
4.7
-
-
14.1
MEDL T 84 △△
6.7
-
-
19.7
MFDL T A4 △△
9.4
-
-
28.2
MFDL T B4 △△
16.5
-
-
42.4
MGDL T C4 △△
20.3
-
-
58.7
MHDL T E4 △△
-
32.3
-
83.7
MHDL T F4 △△
40.1
-
-
103.9

*1: Please refer to “□” and “△△” as per below ;
□Common
   N : Without Safety
   T : With Safety STO
△△ A6L    
   SM : Full Version
   SL : Only Pulse control
△△ A6NL
   NM : Multi-function type
   NL : Standard type
△△ A6BL
   BM : Multi-function type
   BL : Standard type
There are restrictions on combinations. Multifunction type (M suffix is M) has safety function (T in the 5th digit of model number), Position control type, standard type (L at the end of the model number) No safety function (5th digit in the model number is N).

*2: Select and use a motor whose rated current and maximum current do not exceed the values specified.

*3: For AC 200–240 V models in frame sizes C, D, E, and F, adding ‘0C0’ to the end of the part number converts it to the type that supports BiSS‑C.
Part Number Example: MCDL□35B△0C0

System Configuration

Typical system configuration

Typical system configuration

Setup

Setup

Drive appearance

A6L size A

A6SM A-Frame

*: This photo shows multi-functional type. Standard type does not have X3 and X5 connectors.

MENU

Recently checked products

Recently checked product numbers