Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Safety Light Curtain Type 4 Korean Press Machine Compliant SF4B-03 Ver.2 (Discontinued Products)

  • Discontinued Products

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Cautions For Use

Ⅾiscontinued

Last time buy (JST)

September 30, 2022

We are sorry, the products have been discontinued. 
Please refer to the details of the discontinued products and the recommended substitutes list below.

------------------------------ Tab1 showing ------------------------------

Discontinued Products

------------------------------ Tab2 showing ------------------------------

Specifications

Safety light curtain individual specifications

SF4B-F□-03<V2>

TypeMin. sensing object ø14 mm ø0.551 in type
(10 mm 0.394 in beam pitch)
Model No. (Note 2)SF4B-F23-03
<V2>
SF4B-F31-03
<V2>
SF4B-F39-03
<V2>
SF4B-F47-03
<V2>
SF4B-F55-03
<V2>
SF4B-F63-03
<V2>
Number of beam channels233139475563
Protective height
(Note 2)
230 mm
9.055 in
310 mm
12.205 in
390 mm
15.354 in
470 mm
18.504 in
550 mm
21.654 in
630 mm
24.803 in
Current consumptionEmitter: 80 mA or less,
Receiver: 120 mA or less
Emitter: 100 mA or less,
Receiver: 160 mA or less
PFHD2.4 × 10–92.8 × 10–93.2 × 10–93.6 × 10–94.0 × 10–94.4 × 10–9
MTTFD100 years or more
Net weight
(Total of emitter and receiver)
510 g approx.660 g approx.810 g approx.960 g approx.1,100 g approx.1,260 g approx.
TypeMin. sensing object ø14 mm ø0.551 in type
(10 mm 0.394 in beam pitch)
Model No. (Note 2)SF4B-F71-03
<V2>
SF4B-F79-03
<V2>
SF4B-F95-03
<V2>
SF4B-F111-03
<V2>
SF4B-F127-03
<V2>
Number of beam channels717995111127
Protective height
(Note 2)
710 mm
27.953 in
790 mm
31.102 in
950 mm
37.402 in
1,110 mm
43.701 in
1,270 mm
50.000 in
Current consumptionEmitter: 100 mA or less,
Receiver: 160 mA or less
Emitter: 115 mA or less,
Receiver: 190 mA or less
Emitter: 135 mA or less,
Receiver: 230 mA or less
PFHD4.8 × 10–95.2 × 10–96.0 × 10–96.8 × 10–97.6 × 10–9
MTTFD100 years or more
Net weight
(Total of emitter and receiver)
1,420 g approx.1,570 g approx.1,870 g approx.2,170 g approx.2,470 g approx.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The model No.PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)
Notes: 2) In the case of “When used as safety device for presses in China”, the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height.

SF4B-H□-03<V2>

TypeMin. sensing object ø25 mm ø0.984 in type
(20 mm 0.787 in beam pitch)
Model No. (Note 2)SF4B-H12-03
<V2>
SF4B-H16-03
<V2>
SF4B-H20-03
<V2>
SF4B-H24-03
<V2>
SF4B-H28-03
<V2>
Number of beam channels1216202428
Protective height
(Note 2)
230 mm
9.055 in
310 mm
12.205 in
390 mm
15.354 in
470 mm
18.504 in
550 mm
21.654 in
Current consumptionEmitter: 70 mA or less,
Receiver: 95 mA or less
Emitter: 80 mA or less,
Receiver: 115 mA or less
PFHD1.8 × 10–92.0 × 10–92.2 × 10–92.4 × 10–92.6 × 10–9
MTTFD100 years or more
Net weight
(Total of emitter and receiver)
510 g approx.660 g approx.810 g approx.960 g approx.1,100 g approx.
TypeMin. sensing object ø25 mm ø0.984 in type
(20 mm 0.787 in beam pitch)
Model No. (Note 2)SF4B-H32-03
<V2>
SF4B-H36-03
<V2>
SF4B-H40-03
<V2>
SF4B-H48-03
<V2>
SF4B-H56-03
<V2>
Number of beam channels3236404856
Protective height
(Note 2)
630 mm
24.803 in
710 mm
27.953 in
790 mm
31.102 in
950 mm
37.402 in
1,110 mm
43.701 in
Current consumptionEmitter: 80 mA or less,
Receiver: 115 mA or less
Emitter: 90 mA or less,
Receiver: 140 mA or less
Emitter: 100 mA or less,
Receiver: 160 mA or less
PFHD2.8 × 10–93.0 × 10–93.2 × 10–93.6 × 10–94.0 × 10–9
MTTFD100 years or more
Net weight
(Total of emitter and receiver)
1,260 g approx.1,420 g approx.1,570 g approx.1,870 g approx.2,170 g approx.
TypeMin. sensing object ø25 mm ø0.984 in type
(20 mm 0.787 in beam pitch)
Model No. (Note 2)SF4B-H64-03
<V2>
SF4B-H72-03
<V2>
SF4B-H80-03
<V2>
SF4B-H88-03
<V2>
SF4B-H96-03
<V2>
Number of beam channels6472808896
Protective height
(Note 2)
1,270 mm
50.000 in
1,430 mm
56.299 in
1,590 mm
62.598 in
1,750 mm
68.898 in
1,910 mm
75.197 in
Current consumptionEmitter: 100 mA or less,
Receiver: 160 mA or less
Emitter: 110 mA or less,
Receiver: 180 mA or less
Emitter: 120 mA or less,
Receiver: 200 mA or less
PFHD4.4 × 10–94.8 × 10–95.2 × 10–95.6 × 10–96.0 × 10–9
MTTFD100 years or more
Net weight
(Total of emitter and receiver)
2,470 g approx.2,770 g approx.3,070 g approx.3,370 g approx.3,670 g approx.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The model No. PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)
Notes: 2) In the case of “When used as safety device for presses in China”, the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height.

Safety light curtain common specifications

TypeMin. sensing object ø14 mm
ø0.551 in type
Min. sensing object ø25 mm
ø0.984 in type
Model No.SF4B-F□-03<V2>SF4B-H□-03<V2>
Applicable
standards
(Note 2)
International
standard
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JapanJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
Europe (EU)EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe),
EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
North AmericaANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2),
CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,
OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
CE marking directive complianceMachinery Directive, EMC Directive, RoHS Directive
Operating range (Note 3)0.3 to 7 m 0.984 to 22.966 ft12 to 64 beam channels type: 0.3 to 9 m 0.984 to 29.528 ft
72 to 96 beam channels type: 0.3 to 7 m 0.984 to 22.966 ft
Min. sensing object
(Note 4)
ø14 mm ø0.551 in opaque objectø25 mm ø0.984 in opaque object
Effective aperture angle±2.5° or less [for an operating range exceeding 3 m 9.843 ft
(conforming to IEC 61496-2 / UL 61496-2)]
Supply voltage24 V DC ± 10 % Ripple P-P 10 % or less
Control outputs
(OSSD 1, OSSD 2)
PNP open-collector transistor / NPN open-collector transistor (switching method)
・When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA
・Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
・Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA)
(when using 20 m 65.617 ft length cable)
 Operation modeON when all beam channels are received, OFF when one or more beam channels are interrupted
(OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note 5, 6)
Protection circuitIncorporated
Response timeOFF response: 14 ms or less, ON response: 80 to 90 ms
Auxiliary output
(Non-safety output)
PNP open-collector transistor / NPN open-collector transistor (switching method)
・When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA
・Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
・Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA)
(when using 20 m 65.617 ft length cable)
 Operation modeOFF when control outputs are ON, ON when control outputs are OFF.
Protection circuitIncorporated
Responce timeOFF replay: 34 ms or less, ON replay 110 ms or less
Interference prevention functionIncorporated (Note 7)(Available only when in series connection for SF4B-□-03)
Emission halt function /
Interlock function
Incorporated / Incorporated [Manual reset / Auto reset (Note 8)]
External device monitoring functionIncorporated
Optional functions (Note 9)Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
Degree of protectionIP67 / IP65 (IEC)
Ambient temperature-10 to +55 ℃ +14 to +131 ℉
(No dew condensation or icing allowed),
Storage: -25 to +70 ℃ -13 to +158 ℉
Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Ambient illuminanceIncandescent light: 3,500 lx or less at the light-receiving face
Dielectric strength voltage1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Emitting elementInfrared LED (Peak emission wavelength: 870 nm 0.034 mil)
MaterialEnclosure: Aluminium, Upper and lower edges: Iron, Sensing surface: Polycarbonate and Polyester resin, Cap: PBT
Connecting method /
Cable length
Connector /
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note 8)
AccessoriesMS-SFB-2 (Intermediate supporting bracket): (Note 9)
SF4B-TR14 (Test rod): 1 No
MS-SFB-2 (Intermediate supporting bracket): (Note 9)
SF4B-TR25 (Test rod): 1 No

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 ℉.
2) PLe SIL3 compliant from production in August 2009.
3) The operating range is the possible setting distance between the emitter and the receiver.
4) When the floating blanking function is used, the size of the min. sensing object is changed.
5) The outputs are not "OFF" when muting function is active even if the beam channel is interruped.
6) In case the blanking function is valid, the operation mode is changed.
7) Please use 12-core cable.
8) The manual reset and auto reset are possible to be switched depending on the wiring status.
9) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01<V2>,SF4B-□-03<V2> and the SF-C14EX-01.
10) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two safety light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
11) The intermediate supporting bracket (MS-SFB-2) is enclosed with the following models. The number of sets required varies depending on the product.
[1 set]
SF4B-F□<V2>...79 to 111 beam channels
SF4B-H□<V2>...40 to 56 beam channels
SF4B-A□<V2>...20 to 28 beam channels
[2 sets]
SF4B-F127<V2>, SF4B-H□<V2>...64 to 80 beam channels
SF4B-A□<V2>...32 to 40 beam channels
[3 sets]
SF4B-H□<V2>...88 to 96 beam channels
SF4B-A□<V2>...44 to 48 beam channels

Control units

Refer to SF-C10 Specifications Pages for details of the specifications for the control unit SF-C11/C12/C13.

Laser alignment tool

Model No.SF-LAT-2N
Supply voltage3 V (LR6 battery x 2 pcs.)
Battery1.5 V (LR6 battery) x 2 pcs. (replaceable)(Note 2)
Battery lifetime30 hours approx. of continuous operation
(LR6 battery, at +25 ℃ +77 ℉ ambient temperature)
Light sourceRed semiconductor laser: class 2 (IEC / JIS), Class II (FDA)
(Max. output: 1 mW, Peak emission wavelength: 650 nm 0.026 mil)(Note 3)
Spot diameter10 mm 0.394 in approx. (at 5 m 16.404 ft distance)
Ambient temperature0 to +40 ℃ +32 to +104 ℉ (No dew condensation),
Storage: 0 to +55 ℃ +32 to +131 ℉
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
MaterialEnclosure: ABS, Mounting part: Aluminum
WeightNet weight: 150 g approx. (without batteries)

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) LR6 dry cell batteries are not provided with the product. Please purchase them separately.
3) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.

Corner mirror

Model No.RF-SFBH-□
Attenuation rate of
sensing range
With one corner mirror: Declined to 90 %,
With two corner mirrors: Declined to 80 %
(When used in combination with the SF4B series)
Ambient temperature-10 to +55 ℃ +14 to +131 ℉
(No dew condensation or icing allowed),
Storage: -25 to +70 ℃ -13 to +158 ℉
Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Vibration resistance10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
MaterialEnclosure: Aluminum, Mounting bracket: Stainless steel,
Mirror (rear surface mirror): Glass, Side cover: EPDM
AccessoriesIntermediate supporting bracket:
1 set (RF-SFBH-40/48/56/64),
2 sets (RF-SFBH-72/80/88/96)

Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.

------------------------------ Tab3 showing ------------------------------

Dimensions

  • Unit: mm in

Dimensions are the same as SF4B Ver.2 series. Refer to SF4B Ver.2 series dimensions for details.

However, SF4B-03<V2> does not have SF4B-A□ type.
Also, handy-controller SFB-HC cannot be used.

------------------------------ Tab4 showing ------------------------------

I/O Circuit and Wiring diagrams

I/O circuit diagram

<In case of using I/O circuit for PNP output>

I/O circuit diagram In case of using I/O circuit for PNP output

Note: The above diagram is when using a 12-core cable. If an 8-core cable is used, the red, yellow, gray, gray / black, sky-blue / white and sky-blue / black lead wires are absent.

*S1

Switch S1

  • Emission halt input / Reset input
    For manual reset
    Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note 1)
    Open: Emission
    For automatic reset
    Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note 1)
    Open: Emission halt
  • Interlock setting input, Override input, Muting input A / B,
    External device monitoring input
    Vs to Vs – 2.5 V (sink current 5 mA or less): Enabled (Note 1)
    Open: Disabled

Note: Vs is the applying supply voltage.

<In case of using I/O circuit for NPN output>

I/O circuit diagram In case of using I/O circuit for NPN output

Note: The above diagram is when using a 12-core cable. If an 8-core cable is used, the red, yellow, gray, gray / black, sky-blue / white and sky-blue / black lead wires are absent.

*S1

Switch S1

  • Emission halt input / Reset input
    For manual reset
    0 to +1.5 V (source current 5 mA or less): Emission halt
    Open: Emission
    For automatic reset
    0 to +1.5 V (source current 5 mA or less): Emission
    Open: Emission halt
  • Interlock setting input, Override input, Muting input A / B,
    External device monitor input
    0 to +1.5 V (source current 5 mA or less): Enabled
    Open: Disabled

Connection example

Standard components (8-core cable): Interlock function “enabled (manual reset)”, external device monitoring function “enabled”

<In case of using I/O circuit for PNP output>

Connection example In case of using I/O circuit for PNP output

*S1

Switch S1

  • Emission halt input / Reset input
    For manual reset
    Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note)
    Open: Emission
    For automatic reset
    Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note)
    Open: Emission halt

Note: Vs is the applying supply voltage.

The diagram at above shows the configuration when using PNP output, interlock function “enabled (manual reset)” and external device monitoring function “enabled”.

In case of setting the interlock function to “disabled (automatic reset)”

Connection example In case of setting the interlock function to “disabled (automatic reset)”

*Refer to the SF4B<V2> instruction manual for details of the interlock function.


In case of setting the external device monitoring function to “disabled”

Connection example In case of setting the external device monitoring function to “disabled”

*Refer to the SF4B<V2> instruction manual for details of the external device monitoring function.



<In case of using I/O circuit for NPN output>

Connection example In case of using I/O circuit for NPN output

*S1

Switch S1

  • Emission halt input / Reset input
    For manual reset
    0 to +1.5 V (source current 5 mA or less): Emission halt
    Open: Emission
    For automatic reset
    0 to +1.5 V (source current 5 mA or less): Emission
    Open: Emission halt

The diagram at above shows the configuration when using NPN output, interlock function “enabled (manual reset)” and external device monitoring function “enabled”.


In case of setting the interlock function to “disabled (automatic reset)”

Connection example In case of setting the interlock function to “disabled (automatic reset)”

*Refer to the SF4B<V2> instruction manual for details of the interlock function.


In case of setting the external device monitoring function to “disabled”

Connection example In case of setting the external device monitoring function to “disabled”

*Refer to the SF4B<V2>instruction manual for details of the external device monitoring function.



Connection example

Muting control components (12-core cable, with interference prevention wires): Interlock function “disabled (automatic reset)”, external device monitoring function “disabled”

<In case of using I/O circuit for PNP output>

Connection example In case of using I/O circuit for PNP output

*S1

Switch S1

  • Emission halt input / Reset input
    For manual reset
    Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note), Open: Emission
    For automatic reset
    Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note), Open: Emission halt
  • Override input, Muting input A / B, External device monitoring input
    Vs to Vs – 2.5 V (sink current 5 mA or less): Enabled (Note), Open: Disabled

Note: Vs is the applying supply voltage.

The diagram at above shows the configuration when using PNP output, interlock function “disabled (automatic reset)” and external device monitoring function “disabled”.


In case of setting the interlock function to “enabled (manual reset)”

  • When the interlock function is “enabled (manual reset)”, the override function cannot be used.

Connection example In case of setting the interlock function to “enabled (manual reset)”

*Refer to the SF4B<V2> instruction manual for details of the interlock function.


In case of setting the external device monitoring function to “enabled”

Connection example In case of setting the external device monitoring function to “enabled”

*Refer to the SF4B<V2> instruction manual for details of the external device monitoring function.


<In case of using I/O circuit for NPN output>

Connection example In case of using I/O circuit for NPN output

*S1

Switch S1

  • Emission halt input / Reset input
    For manual reset
    0 to +1.5 V (source current 5 mA or less): Emission halt, Open: Emission
    For automatic reset
    0 to +1.5 V (source current 5 mA or less): Emission, Open: Emission halt
  • Override input, Muting input A / B, External device monitoring input
    0 to +1.5 V (source current 5 mA or less): Enabled, Open: Disabled

The diagram at above shows the configuration when using NPN output, interlock function “disabled (automatic reset)” and external device monitoring function “disabled”.


In case of setting the interlock function to “enabled (manual reset)”

  • When the interlock function is “enabled (manual reset)”, the override function cannot be used.

Connection example In case of setting the interlock function to “enabled (manual reset)”

*Refer to the SF4B<V2> instruction manual for details of the interlock function.


In case of setting the external device monitoring function to “enabled”

Connection example In case of setting the external device monitoring function to “enabled”

*Refer to the SF4B<V2> instruction manual for details of the external device monitoring function.



SF-C11

SF4B / SF4B-G series wiring diagram (Control Category 4)

For PNP output (minus ground)

  • Set the safety light curtain input polarity selection switch to the PNP side and ground the 0 V line.

SF-C11 For PNP output (minus ground)

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Emission halt occurs when the test (TEST) button is open, and emission occurs when the test (TEST) button is short-circuited. If not using the test (TEST) button, short-circuit T1 and T2.

For NPN output (plus ground)

  • In the above diagram, set the safety light curtain input polarity selection switch to the NPN side and ground the + side.

SF4B series wiring diagram (Control Category 4) For NPN output (plus ground)


When SF-C11 is connected to the safety light curtain, be sure to use the following mating cable.
SFB-CB□, SFB-CCJ10□



Terminal arrangement diagram

SF-C11 Terminal arrangement diagram

TerminalFunction
A1+24 V DC
A20 V
13-14, 23-24, 33-34Safety output (NO contact × 3)
41-42Auxiliary output (NC contact × 1)
X1Reset output terminal
X2Reset input terminal (Manual)
X3Reset input terminal (Automatic)
ANot used
B
T1Test output terminal
T2Test input terminal
AUXSemiconductor auxiliary output


Pin layout for safety light curtain connectors

SF-C11 Pin layout for safety light curtain connectors

Connector pin No.Emitter side connectorReceiver side connector
InterlockOSSD 2
+24 V DC+24 V DC
Emission haltOSSD 1
Auxiliary outputEDM (External relay monitor)
Synchronization wire +Synchronization wire +
Synchronization wire –Synchronization wire –
0 V0 V
Shield wireShield wire

SF-C12

SF4B / SF4B-G series wiring diagram (Control Category 4)

For PNP output (minus ground)

  • Set the two safety light curtain input polarity select switches to the PNP side and connect the FG terminal to the 0 V line.

SF-C12 SF4B series wiring diagram (Control Category 4)

Note: The above diagram is when using manual reset. If automatic reset is used, connect a normally closed type pushbutton switch between T1 and T2 and leave between X1 and X2 open.

For NPN output (plus ground)

  • In the above diagram, set the two safety light curtain input polarity selection switches to the NPN side and connect the F.G. terminal to the + side.

When SF-C12 is connected to the safety light curtain, be sure to use the following mating cable.
SFB-CB05-MU, SFB-CCJ10□-MU

Terminal arrangement diagram

SF-C12 Terminal arrangement diagram

TerminalFunction
FGFrame ground (F.G.) terminal
A20 V
A1+24 V DC
13-14, 23-24Safety output (NO contact × 2)
31-32Auxiliary output (NC contact × 1)
FB4External relay monitor terminal 2
FB3
FB2External relay monitor terminal 1
FB1
TerminalFunction
R+Interference prevention wire – (Receiver side)
R–Interference prevention wire + (Receiver side)
E+Interference prevention wire – (Emitter side)
E–Interference prevention wire + (Emitter side)
T2Emission halt input terminal
T1
X2Automatic reset / manual reset selection terminal
Manual reset: X1 – X2 short-circuited
X1

Pin layout for safety light curtain connectors

SF-C12 Pin layout for safety light curtain connectors

Note: Input and output for pin Nos. ⑪ and ⑫ are not used by this device.

Connector pin No.Emitter side connectorReceiver side connector
InterlockOSSD 2
+24 V DC+24 V DC
Emission haltOSSD 1
Auxiliary outputEDM (External relay monitor)
Synchronization wire +Synchronization wire +
Synchronization wire –Synchronization wire –
0 V0 V
Shield wireShield wire
Interference prevention wire +Interference prevention wire +
Interference prevention wire –Interference prevention wire –
(Override input)(Muting input 1)
(Muting lamp output)(Muting input 2)

SF-C13

SF4B / SF4B-G series wiring diagram (Control Category 4)

For PNP output (minus ground)

  • Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively.

SF-C13 For PNP output (minus ground)

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2)Use a momentary-type switch as the reset (RESET) button.

For NPN output (plus ground)

  • Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side.

SF-C13 For NPN output (plus ground)

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.

When SF-C13 is connected to the safety light curtain, be sure to use the following descrete wire mating cable.
SFB-CCB□(-MU), SFB-CC□(-MU)

Terminal arrangement diagram

SF-C13 Terminal arrangement diagram

TerminalFunction
A1+24 V DC
A20 V
S1 to S4Safety light curtain control output (OSSD) input terminal
AUXSemiconductor auxiliary output
X1Reset output terminal
X2Reset input terminal (Manual)
X3Reset input terminal (Automatic)
13-14, 23-24, 33-34Safety output (NO contact × 3)
41-42Auxiliary output (NC contact × 1)

A terminal block is required for wiring of safety light curtain side.

------------------------------ Tab5 showing ------------------------------

Cautions For Use

■ Information on SF4B series Ver.2

Attentions of SF4B-03 Ver.2 series are the same as SF4B Ver.2 series. Refer to SF4B Ver.2 series for details.

>>Go to Safety Light Curtain Type 4 SF4B Ver.2

MENU

Recently checked products

Recently checked product numbers