Item | Specifications | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Part Number | SG-A1-02-5 | |||||||||||||||||||||||||||||||
Product Number | SG-A1-02-5 | |||||||||||||||||||||||||||||||
Products Name | Ultra-slim Safety door switch | |||||||||||||||||||||||||||||||
Door monitor contacts | 2NC | |||||||||||||||||||||||||||||||
Cable length | 5 m 16.404 ft | |||||||||||||||||||||||||||||||
Applicable standards | EN 60947-5-1, GS-ET-15 | |||||||||||||||||||||||||||||||
Applicable standards : Standards for use | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 | |||||||||||||||||||||||||||||||
Applicable regulations | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] | |||||||||||||||||||||||||||||||
Operating condition : Ambient temperature | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | |||||||||||||||||||||||||||||||
Operating condition : Ambient humidity | 45 to 85 % RH | |||||||||||||||||||||||||||||||
Operating condition : Pollution degree | 3 (Inside 2) | |||||||||||||||||||||||||||||||
Operating condition : Altitude | 2,000 m 6,561.68 ft max. | |||||||||||||||||||||||||||||||
Impulse withstand voltage (Uimp) | 4 kV | |||||||||||||||||||||||||||||||
Rated insulation voltage (Ui) | 300 V | |||||||||||||||||||||||||||||||
Thermal current (Ith) | 2.5 A | |||||||||||||||||||||||||||||||
Rated operational voltage (Ue) / Rated operational current (Ie) |
| |||||||||||||||||||||||||||||||
Electric shock protection class | Class II (IEC 61140), 回(double insulated) | |||||||||||||||||||||||||||||||
Protection | IP 67 (IEC 60529) | |||||||||||||||||||||||||||||||
Shock resistance | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 | |||||||||||||||||||||||||||||||
Vibration resistance | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | |||||||||||||||||||||||||||||||
Operating frequency | 1,200 operations/hour | |||||||||||||||||||||||||||||||
Actuator operating speed | 0.05 to 1.0 m/sec. | |||||||||||||||||||||||||||||||
B10D | 2,000,000 (ISO 13849-1 Annex C Table C.1) | |||||||||||||||||||||||||||||||
Mechanical durability | 1,000,000 operations min. (GS-ET-15) | |||||||||||||||||||||||||||||||
Electrical durability | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) | |||||||||||||||||||||||||||||||
Direct opening travel | 8 mm 0.315 in min. | |||||||||||||||||||||||||||||||
Direct opening force | 60 N min. | |||||||||||||||||||||||||||||||
Contact resistance | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | |||||||||||||||||||||||||||||||
Short-circuit protective device | Use 250 V / 10 A fast acting type fuse | |||||||||||||||||||||||||||||||
Conditional short-circuit current | 50 A (250 V) | |||||||||||||||||||||||||||||||
Material | Enclosure : PA66 | |||||||||||||||||||||||||||||||
Cable | UL style 2464, No.20 AWG 6-core | |||||||||||||||||||||||||||||||
Weight | Approx. 420 g |