Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Cylindrical Inductive Proximity Sensor [Amplifier Built-in / DC 3-wire Type] GX-300

  • Basic Information

  • Application

  • Order guide

  • Number

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Sensing characteristics

  • Cautions For Use

------------------------------ Tab1 showing ------------------------------

Basic Information

Standard Type Cylindrical Inductive Proximity Sensors with Improved Basic Performance

UL,CE,UKCA Approved

UL : Listing(Excluding small-diameter type)
UL : Recognition(Small-diameter type only. Excluding bendingresistant cable type.)

------------------------------ Tab2 showing ------------------------------

Cautions For Use

Positioning processing equipment

加工機の位置決め

------------------------------ Tab3 showing ------------------------------

Order guide

Model No.

Model No.

DC 3-wire type (Small-diameter, shielded type)

TypeAppearance
(mm in)
Sensing range (Note)Model No.OutputOutput operation
Max.
operation
distance
Stable
sensing
range
Non-threaded
type

0.8mm
0.031 in
0 to 0.56mm
0 to 0.022 in
GX-303S-A-NNPN open-collector
transistor
Normally open
GX-303S-B-NNormally closed
GX-303S-A-PPNP open-collector
transistor
Normally open
GX-303S-B-PNormally closed

1.2mm
0.047 in
0 to 0.84mm
0 to 0.033 in
GX-304S-A-NNPN open-collector
transistor
Normally open
GX-304S-B-NNormally closed
GX-304S-A-PPNP open-collector
transistor
Normally open
GX-304S-B-PNormally closed

1mm
0.039 in
0 to 0.7mm
0 to 0.028 in
GX-305S-A-NNPN open-collector
transistor
Normally open
GX-305S-B-NNormally closed
GX-305S-A-PPNP open-collector
transistor
Normally open
GX-305S-B-PNormally closed
Threaded
type

1.2mm
0.047 in
0 to 0.84mm
0 to 0.033 in
GX-305M-A-NNPN open-collector
transistor
Normally open
GX-305M-B-NNormally closed
GX-305M-A-PPNP open-collector
transistor
Normally open
GX-305M-B-PNormally closed

Note:

The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

DC 3-wire type (Shielded type)

Threaded type

TypeAppearance
(mm in)
Sensing range (Note 1)Model No.
(Note 2)
OutputOutput operation
Max.
operation
distance
Stable
sensing
range
Standard
sensing
range
type

1.5mm
0.059 in
0 to 1.2mm
0 to 0.047 in
GX-308M-A-NNPN open-collector
transistor
Normally open
GX-308M-B-NNormally closed
GX-308M-A-PPNP open-collector
transistor
Normally open
GX-308M-B-PNormally closed

2mm
0.079 in
0 to 1.6mm
0 to 0.063 in
GX-312M-A-NNPN open-collector
transistor
Normally open
GX-312M-B-NNormally closed
GX-312M-A-PPNP open-collector
transistor
Normally open
GX-312M-B-PNormally closed

5mm
0.197 in
0 to 4mm
0 to 0.157 in
GX-318M-A-NNPN open-collector
transistor
Normally open
GX-318M-B-NNormally closed
GX-318M-A-PPNP open-collector
transistor
Normally open
GX-318M-B-PNormally closed

10mm
0.394 in
0 to 8mm
0 to 0.315 in
GX-330M-A-NNPN open-collector
transistor
Normally open
GX-330M-B-NNormally closed
GX-330M-A-PPNP open-collector
transistor
Normally open
GX-330M-B-PNormally closed
Long
sensing
range
type

2mm
0.079 in
0 to 1.6mm
0 to 0.063 in
GX-308MK-A-NNPN open-collector
transistor
Normally open
GX-308MK-B-NNormally closed
GX-308MK-A-PPNP open-collector
transistor
Normally open
GX-308MK-B-PNormally closed

4mm
0.157 in
0 to 3.2mm
0 to 0.126 in
GX-312MK-A-NNPN open-collector
transistor
Normally open
GX-312MK-B-NNormally closed
GX-312MK-A-PPNP open-collector
transistor
Normally open
GX-312MK-B-PNormally closed

8mm
0.315 in
0 to 6.4mm
0 to 0.252 in
GX-318MK-A-NNPN open-collector
transistor
Normally open
GX-318MK-B-NNormally closed
GX-318MK-A-PPNP open-collector
transistor
Normally open
GX-318MK-B-PNormally closed

15mm
0.591 in
0 to 12mm
0 to 0.472 in
GX-330MK-A-NNPN open-collector
transistor
Normally open
GX-330MK-B-NNormally closed
GX-330MK-A-PPNP open-collector
transistor
Normally open
GX-330MK-B-PNormally closed

Notes:

1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

2) The PNP output, normally open type models [GX-3□M(K)-A-P(-□)] are compatible with IO-Link.
The PNP output, normally closed type models and all NPN output type models do not support IO-Link.

DC 3-wire type (Non-shielded type)

Threaded type

TypeAppearance
(mm in)
Sensing range (Note 1)Model No.
(Note 2)
OutputOutput operation
Max.
operation
distance
Stable
sensing
range
Standard
sensing
range
type

2mm
0.079 in
0 to 1.6mm
0 to 0.063 in
GX-308ML-A-NNPN open-collector
transistor
Normally open
GX-308ML-B-NNormally closed
GX-308ML-A-PPNP open-collector
transistor
Normally open
GX-308ML-B-PNormally closed

5mm
0.197 in
0 to 4mm
0 to 0.157 in
GX-312ML-A-NNPN open-collector
transistor
Normally open
GX-312ML-B-NNormally closed
GX-312ML-A-PPNP open-collector
transistor
Normally open
GX-312ML-B-PNormally closed

10mm
0.394 in
0 to 8mm
0 to 0.315 in
GX-318ML-A-NNPN open-collector
transistor
Normally open
GX-318ML-B-NNormally closed
GX-318ML-A-PPNP open-collector
transistor
Normally open
GX-318ML-B-PNormally closed

18mm
0.709 in
0 to 14.4mm
0 to 0.567 in
GX-330ML-A-NNPN open-collector
transistor
Normally open
GX-330ML-B-NNormally closed
GX-330ML-A-PPNP open-collector
transistor
Normally open
GX-330ML-B-PNormally closed
Long
sensing
range
type

4mm
0.157 in
0 to 3.2mm
0 to 0.126 in
GX-308MLK-A-NNPN open-collector
transistor
Normally open
GX-308MLK-B-NNormally closed
GX-308MLK-A-PPNP open-collector
transistor
Normally open
GX-308MLK-B-PNormally closed

8mm
0.315 in
0 to 6.4mm
0 to 0.252 in
GX-312MLK-A-NNPN open-collector
transistor
Normally open
GX-312MLK-B-NNormally closed
GX-312MLK-A-PPNP open-collector
transistor
Normally open
GX-312MLK-B-PNormally closed

16mm
0.630 in
0 to 12.8mm
0 to 0.504 in
GX-318MLK-A-NNPN open-collector
transistor
Normally open
GX-318MLK-B-NNormally closed
GX-318MLK-A-PPNP open-collector
transistor
Normally open
GX-318MLK-B-PNormally closed

30mm
1.181 in
0 to 24mm
0 to 0.945 in
GX-330MLK-A-NNPN open-collector
transistor
Normally open
GX-330MLK-B-NNormally closed
GX-330MLK-A-PPNP open-collector
transistor
Normally open
GX-330MLK-B-PNormally closed

Notes :

1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

2) The PNP output, normally open type models [GX-3□ML(K)-A-P(-□)] are compatible with IO-Link.
The PNP output, normally closed type models and all NPN output type models do not support IO-Link.

5 m 16.404 ft cable length type

5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available. When ordering this type, suffix "-C5" to the model No.
(e.g.) 5 m 16.404 ft cable length type of GX-303S-A-N is "GX-303S-A-N-C5".

Bending-resistant cable type (2 m 6.562 ft / 5 m 16.404 ft cable length)

The shielded, non-threaded type sensors (ø4 mm ø0.157 in / ø5.4 mm ø0.213 in) and threaded type sensors (M5 / M8) are available with a bending-resistant cable (cable length: 2 m 6.562 ft or 5 m 16.404 ft). (Note that the ø5.4 mm ø0.213 in size, normally closed type sensors are not available with a 5-m-long bending-resistant cable.)
When ordering bending-resistant 2 m 6.562 ft cable type, suffix "-R" to the model No. When ordering bending-resistant 5 m 16.404 ft cable type, suffix "-R5" to the model No.
(e.g.) Bending-resistant 2 m 6.562 ft cable type of GX-304S-A-N is "GX-304S-A-N-R".
(e.g.) Bending-resistant 5 m 16.404 ft cable type of GX-304S-A-N is "GX-304S-A-N-R5".

Pigtailed type

The threaded type sensors (M8 / M12 / M18 / M30) are available in the pigtailed type. (Connector: M12)
When ordering this type, suffix "-J" to the model No.
(e.g.) Pigtailed type of GX-308M-A-N is "GX-308M-A-N-J".

Please purchase mating cables separately when using pigtailed type models.

Mating cable

Mating cable

Model No.Description
CN-24S-C2Length: 2 m 6.562 ftAWG20 4-core cable with M12 Smartclick connector on one end
Cable outside diameter: ø6 mm ø0.236 in
CN-24S-C5Length: 5 m 16.404 ft

Note :is a trademark of OMRON Corporation.

Connector type

The threaded type sensors (M12 / M18 / M30) are available in the connector type. When ordering this type, suffix "-Z" to the model No.
(e.g.) Connector type of GX-312M-A-N is "GX-312M-A-N-Z".

List of connection systems

Please see the list below for the model no. of each model.

>>List of connection systems

------------------------------ Tab4 showing ------------------------------

List of connection systems

Please check the "Order guide" page for the model with a standard cable of 2 m.

 

DC 3-wire type (Small-diameter, shielded type)

Type5 m 16.404 ft
cable length
("-C5" at the end of model No.)
Bending-resistant
2 m 6.562 ft cable
("-R" at the end of model No.)
Bending-resistant
5 m 16.404 ft cable
("-R5" at the end of model No.)
Pigtailed type
("-J" at the end of model No.)
Connector type
("-Z" at the end of model No.)
ø3.0mm
ø0.118 in
GX-303S-A-N-C5----
GX-303S-B-N-C5----
GX-303S-A-P-C5----
GX-303S-B-P-C5----
ø4.0mm
ø0.157 in
GX-304S-A-N-C5GX-304S-A-N-RGX-304S-A-N-R5--
GX-304S-B-N-C5GX-304S-B-N-RGX-304S-B-N-R5--
GX-304S-A-P-C5GX-304S-A-P-RGX-304S-A-P-R5--
GX-304S-B-P-C5GX-304S-B-P-RGX-304S-B-P-R5--
ø5.4mm
ø0.213 in
GX-305S-A-N-C5GX-305S-A-N-RGX-305S-A-N-R5--
GX-305S-B-N-C5GX-305S-B-N-R---
GX-305S-A-P-C5GX-305S-A-P-RGX-305S-A-P-R5--
GX-305S-B-P-C5GX-305S-B-P-R---
M5GX-305M-A-N-C5GX-305M-A-N-RGX-305M-A-N-R5--
GX-305M-B-N-C5GX-305M-B-N-RGX-305M-B-N-R5--
GX-305M-A-P-C5GX-305M-A-P-RGX-305M-A-P-R5--
GX-305M-B-P-C5GX-305M-B-P-RGX-305M-B-P-R5--

 


DC 3-wire type (Shielded type) [Standard sensing range type]

 

Note: Please purchase mating cables separately when using pigtailed type models.

>>Refer to Mating cable

DC 3-wire type (Shielded type)[Long sensing range type]

 
Note: Please purchase mating cables separately when using pigtailed type models.
>>Refer to Mating cable 

DC 3-wire type (Non-shielded type) [Standard sensing range type]

 
 
Note: Please purchase mating cables separately when using pigtailed type models.
>>Refer to Mating cable

DC 3-wire type (Non-shielded type) [Long sensing range type]

------------------------------ Tab5 showing ------------------------------

Specifications

DC 3-wire type (Small-diameter, shielded type)

TypeSmall-diameter, shielded type
Non-threaded typeThreaded type
Model No.
(Note 2)
Normally
open
GX-303S-A-□GX-304S-A-□GX-305S-A-□GX-305M-A-□
Normally
closed
GX-303S-B-□GX-304S-B-□GX-305S-B-□GX-305M-B-□
Regulatory complianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL Recognition Certification (excluding bending-resistant cable type)
Max. operation distance
(Note 3)
0.8 mm 0.031 in ±10 %1.2 mm 0.047 in ±10 %1.0 mm 0.039 in ±10 %1.2 mm 0.047 in ±10 %
Stable sensing range (Note 3)0 to 0.56 mm
0 to 0.022 in
0 to 0.84 mm
0 to 0.033 in
0 to 0.7 mm
0 to 0.028 in
0 to 0.84 mm
0 to 0.033 in
Standard sensing objectIron sheet
3 × 3 × t 1 mm
0.118 × 0.118 × t 0.039 in
Iron sheet
4 × 4 × t 1 mm
0.157 × 0.157 × t 0.039 in
Iron sheet
5.4 × 5.4 × t 1 mm
0.213 × 0.213 × t 0.039 in
Iron sheet
4 × 4 × t 1 mm
0.157 × 0.157 × t 0.039 in
Hysteresis15 % or less of operation distance (with standard sensing object)
Supply voltage (Note 4)10 to 30 V DC [including 10 % ripple (p-p)]
Current consumption10 mA or less
Output (Note 5)<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA or less (50 mA or less for GX-303S)
• Applied voltage: 30 V DC or less (between output to 0 V)
• Residual voltage: 2 V or less (Note 6) (at max. sink current)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA or less (50 mA or less for GX-303S)
• Applied voltage: 30 V DC or less (between output to +V)
• Residual voltage: 2 V or less (Note 6) (at max. source current)
 Short-circuit protectionIncorporated
Response frequency (Note 7)5 kHz4 kHz
Operation indicatorOrange LED (lights up when the output is ON)
Pollution degree3
Altitude2,000 m 6561.68 ft or less
Environmental
resistance
ProtectionIP67 (IEC)
Ambient
temperature
-25 to +70 ℃ -13 to +158 ℉, Storage: -25 to +70 ℃ -13 to +158 ℉ (No condensation or icing allowed)
Ambient
humidity
35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed)
Voltage
withstandability
500 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration
resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock
resistance
500 m/s2 acceleration in X, Y and Z directions ten times each
Sensing range
variation
Temperature
characteristics
Within ±15 % of sensing range at +23 ℃ +73 ℉ in ambient temperature range
Voltage
characteristics
Within ±2.5 % for ±15 % fluctuation of the rated supply voltage
MaterialEnclosure: Stainless steel (SUS303) [Brass (Nickel plated) for GX-305S]
Sensing part: Heat-resistant ABS, Cable: Polyvinyl chloride (PVC)
Mating cable0.09 mm2 3-core ø2.4 mm ø0.094 in cabtyre cable, 2 m 6.562 ft long0.14 mm2 3-core ø2.9 mm ø0.114 in cabtyre cable, 2 m 6.562 ft long (Note 8)
Weight (Note 6)Net weight: 20 g approx.
Gross weight: 40 g approx.
Net weight: 25 g approx.
Gross weight: 50 g approx.
Net weight: 30 g approx.
Gross weight: 50 g approx.
Accessories-Nut: 2 pcs.,
Toothed lock washer: 1 pc.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73 ℉.

2) The sensors with "N" indicated instead of □ in their model Nos. are NPN output type. The sensors with "P" are PNP output type.

3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

4) When used at a power of 12 V, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained.

5) When the output is 20 mA or less, the product is less susceptible to the effects of internal self-heat generation and therefore a more stable repeat accuracy can be obtained.

6) When the cable length is 2 m 6.562 ft.

7) The response frequency is an average value.

8) The bending-resistant cable type models come with a 0.15 mm2 3-core bending-resistant ø2.9 mm ø0.114 in cabtyre cable.

DC 3-wire type (Shielded type)

TypeShielded type
Threaded type
Standard sensing range
Model No.
(Note 2)
Normally openGX-308M-A-□GX-312M-A-□GX-318M-A-□GX-330M-A-□
Normally closedGX-308M-B-□GX-312M-B-□GX-318M-B-□GX-330M-B-□
Regulatory complianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing Certification
Max. operation distance
(Note 3)
1.5 mm
0.059 in ±10 %
2 mm
0.079 in ±10 %
5 mm
0.197 in ±10 %
10 mm
0.394 in ±10 %
Stable sensing range
(Note 3)
0 to 1.2 mm
0 to 0.047 in
0 to 1.6 mm
0 to 0.063 in
0 to 4 mm
0 to 0.157 in
0 to 8 mm
0 to 0.315 in
Standard sensing objectIron sheet
8 × 8 × t 1 mm
0.315 × 0.315× t 0.039 in
Iron sheet
12 × 12 × t 1 mm
0.472 × 0.472× t 0.039 in
Iron sheet
18 × 18 × t 1 mm
0.709 × 0.709× t 0.039 in
Iron sheet
30 × 30 × t 1 mm
1.181 × 1.181× t 0.039 in
Hysteresis10 % or less of operation distance (with standard sensing object)
Supply voltage10 to 30 V DC [including 10 % ripple (p-p)], Class 2
Current consumption16 mA or less
Output
(C/Q)
(Note 4)
IO-Link
communication
IO-Link Specification Ver1.1
Baud rateCOM3 (230.4 kbps)
Process dataPD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)
Minimum
cycle time
0.4 ms
Vendor ID834 (0x342)
Device IDGX-308□: 0x70000, GX-312□: 0x70001, GX-318□: 0x70002, GX-330□: 0x70003
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 200 mA or less
[GX-308M(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to 0 V)
• Residual voltage: 2 V or less (Note 5) (at sink current 200 mA or less)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 200 mA or less
[GX-308M(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to +V)
• Residual voltage: 2 V or less (Note 5) (at source current 200 mA or less)
 Short-circuit protectionIncorporated
Response frequency (Note 6)2,000 Hz1,500 Hz600 Hz400 Hz
Operation indicatorStandard I/O mode (SIO mode): Operation indicator (orange, ON), Communication indicator (green, OFF)
IO-LINK communication mode (COM mode): Operation indicator (orange, ON), Communication indicator [green, flashing (1-sec intervals)]
Pollution degree3
Altitude2,000 m 6561.68 ft or less
Environmental
resistance
ProtectionIP67 (IEC), IP69K, IP67G [IP67 (IEC), IP69K for connector type]
Ambient
temperature
-40 to +85 ℃ -40 to +185 ℉, Storage: -45 to +85 ℃ -49 to +185 ℉ (No condensation or icing allowed)
(UL temperature rating for pigtailed type: -25 to +70 ℃ -13 to +158 ℉)
Ambient
humidity
35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed)
Voltage
withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration
resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock
resistance
1,000 m/s2 (GX-308M(K)-□: 500 m/s2) acceleration in X, Y and Z directions ten times each
Sensing
range
variation
Temperature
characteristics
Within ±15% of sensing range at +23 ℃ +73 ℉ in ambient temperature range
Within ±10% of sensing range at +23 ℃ +73 ℉ in temperature range of -25 to +70 ℃ -13 to +158 ℉
Voltage
characteristics
Within ±1% for ±15 % fluctuation of the rated supply voltage
MaterialEnclosure: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-□],
Sensing part: Polybutylene terephthalate (PBT), Cable: Polyvinyl chloride (PVC)
Mating cable0.2 mm2 3-core oil resistant ø4 mm ø0.157 in cabtyre cable, 2 m 6.562 ft long (Note 7)0.2 mm2 3-core oil resistant ø6 mm ø0.236 in cabtyre cable, 2 m 6.562 ft long (Note 8)
WeightCable type
(Note 5)
Net weight:
55 g approx.
Gross weight:
80 g approx.
Net weight:
70 g approx.
Gross weight:
95 g approx.
Net weight:
140 g approx.
Gross weight:
160 g approx.
Net weight:
210 g approx.
Gross weight:
240 g approx.
Pigtailed typeNet weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
40 g approx.
Gross weight:
70 g approx.
Net weight:
70 g approx.
Gross weight:
100 g approx.
Net weight:
140 g approx.
Gross weight:
170 g approx.
Connector
type
-Net weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
50 g approx.
Gross weight:
75 g approx.
Net weight:
130 g approx.
Gross weight:
150 g approx.
AccessoriesNut: 2 pcs., Toothed lock washer: 1 pc.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73 ℉.

2) The sensors with "N" indicated instead of □ in their model No. are NPN output type. The sensors with "P" are PNP output type.

3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

4) PNP output, normally closed type models and all NPN output models do not support IO-Link.

5) When the cable length is 2 m 6.562 ft.

6) The response frequency is an average value.

7) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø4 mm ø0.157 in cabtyre cable.

8) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø6 mm ø0.236 in cabtyre cable.

TypeShielded type
Threaded type
Long sensing range
Model No.
(Note 2)
Normally openGX-308MK-A-□GX-312MK-A-□GX-318MK-A-□GX-330MK-A-□
Normally closedGX-308MK-B-□GX-312MK-B-□GX-318MK-B-□GX-330MK-B-□
Regulatory complianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing Certification
Max. operation distance
(Note 3)
2 mm
0.079 in ±10 %
4 mm
0.157 in ±10 %
8 mm
0.315 in ±10 %
15 mm
0.591 in ±10 %
Stable sensing range
(Note 3)
0 to 1.6 mm
0 to 0.063 in
0 to 3.2 mm
0 to 0.126 in
0 to 6.4 mm
0 to 0.252 in
0 to 12 mm
0 to 0.472 in
Standard sensing objectIron sheet
8 × 8 × t 1 mm
0.315 × 0.315× t 0.039 in
Iron sheet
12 × 12 × t 1 mm
0.472 × 0.472× t 0.039 in
Iron sheet
24 × 24 × t 1 mm
0.945 × 0.945× t 0.039 in
Iron sheet
45 × 45 × t 1 mm
1.772 × 1.772× t 0.039 in
Hysteresis15 % or less of operation distance (with standard sensing object)
Supply voltage10 to 30 V DC [including 10 % ripple (p-p)], Class 2
Current consumption16 mA or less
Output
(C/Q)
(Note 4)
IO-Link
communication
IO-Link Specification Ver1.1
Baud rateCOM3 (230.4 kbps)
Process dataPD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)
Minimum
cycle time
0.4 ms
Vendor ID834 (0x342)
Device IDGX-308□: 0x70000, GX-312□: 0x70001, GX-318□: 0x70002, GX-330□: 0x70003
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 200 mA or less
[GX-308M(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to 0 V)
• Residual voltage: 2 V or less (Note 5) (at sink current 200 mA or less)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 200 mA or less
[GX-308M(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to +V)
• Residual voltage: 2 V or less (Note 5) (at source current 200 mA or less)
 Short-circuit protectionIncorporated
Response frequency (Note 6)1,500 Hz1,000 Hz500 Hz250 Hz
Operation indicatorStandard I/O mode (SIO mode): Operation indicator (orange, ON), Communication indicator (green, OFF)
IO-LINK communication mode (COM mode): Operation indicator (orange, ON), Communication indicator [green, flashing (1-sec intervals)]
Pollution degree3
Altitude2,000 m 6561.68 ft or less
Environmental
resistance
ProtectionIP67 (IEC), IP69K, IP67G [IP67 (IEC), IP69K for connector type]
Ambient
temperature
-40 to +85 ℃ -40 to +185 ℉, Storage: -45 to +85 ℃ -49 to +185 ℉ (No condensation or icing allowed)
(UL temperature rating for pigtailed type: -25 to +70 ℃ -13 to +158 ℉)
Ambient
humidity
35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed)
Voltage
withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration
resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock
resistance
1,000 m/s2 (GX-308M(K)-□: 500 m/s2) acceleration in X, Y and Z directions ten times each
Sensing
range
variation
Temperature
characteristics
Within ±15% of sensing range at +23 ℃ +73 ℉ in ambient temperature range
Within ±10% of sensing range at +23 ℃ +73 ℉ in temperature range of -25 to +70 ℃ -13 to +158 ℉
Voltage
characteristics
Within ±1% for ±15 % fluctuation of the rated supply voltage
MaterialEnclosure: Nickel-plated brass [stainless steel (SUS303) for GX-308M(K)-□],
Sensing part: Polybutylene terephthalate (PBT), Cable: Polyvinyl chloride (PVC)
Mating cable0.2 mm2 3-core oil resistant ø4 mm ø0.157 in cabtyre cable, 2 m 6.562 ft long (Note 7)0.2 mm2 3-core oil resistant ø6 mm ø0.236 in cabtyre cable, 2 m 6.562 ft long (Note 8)
WeightCable type
(Note 5)
Net weight:
55 g approx.
Gross weight:
80 g approx.
Net weight:
70 g approx.
Gross weight:
95 g approx.
Net weight:
140 g approx.
Gross weight:
160 g approx.
Net weight:
210 g approx.
Gross weight:
240 g approx.
Pigtailed typeNet weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
40 g approx.
Gross weight:
70 g approx.
Net weight:
70 g approx.
Gross weight:
100 g approx.
Net weight:
140 g approx.
Gross weight:
170 g approx.
Connector
type
-Net weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
50 g approx.
Gross weight:
75 g approx.
Net weight:
130 g approx.
Gross weight:
150 g approx.
AccessoriesNut: 2 pcs., Toothed lock washer: 1 pc.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73 ℉.

2) The sensors with "N" indicated instead of □ in their model No. are NPN output type. The sensors with "P" are PNP output type.

3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

4) PNP output, normally closed type models and all NPN output models do not support IO-Link.

5) When the cable length is 2 m 6.562 ft.

6) The response frequency is an average value.

7) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø4 mm ø0.157 in cabtyre cable.

8) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø6 mm ø0.236 in cabtyre cable.

DC 3-wire type (Non-shielded type)

TypeNon-shielded type
Threaded type
Standard sensing range
Model No.
(Note 2)
Normally openGX-308ML-A-□GX-312ML-A-□GX-318ML-A-□GX-330ML-A-□
Normally closedGX-308ML-B-□GX-312ML-B-□GX-318ML-B-□GX-330ML-B-□
Regulatory complianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing Certification
Max. operation distance
(Note 3)
2 mm
0.079 in ±10 %
5 mm
0.197 in ±10 %
10 mm
0.394 in ±10 %
18 mm
0.709 in ±10 %
Stable sensing range
(Note 3)
0 to 1.6 mm
0 to 0.063 in
0 to 4 mm
0 to 0.157 in
0 to 8 mm
0 to 0.315 in
0 to 14.4 mm
0 to 0.567 in
Standard sensing objectIron sheet
8 × 8 × t 1 mm
0.315 × 0.315 × t 0.039 in
Iron sheet
15 × 15 × t 1 mm
0.591 × 0.591 × t 0.039 in
Iron sheet
30 × 30 × t 1 mm
1.181 × 1.181 × t 0.039 in
Iron sheet
54 × 54 × t 1 mm
2.126 × 2.126 × t 0.039 in
Hysteresis10 % or less of operation distance (with standard sensing object)
Supply voltage10 to 30 V DC [including 10 % ripple (p-p)], Class 2
Current consumption16 mA or less
Output
(C/Q)
(Note 4)
IO-Link
communication
IO-Link Specification Ver1.1
Baud rateCOM3 (230.4 kbps)
Process dataPD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)
Minimum
cycle time
0.4 ms
Vendor ID834 (0x342)
Device IDGX-308□: 0x70000, GX-312□: 0x70001, GX-318□: 0x70002, GX-330□: 0x70003
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 200 mA or less
[GX-308ML(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to 0 V)
• Residual voltage: 2 V or less (Note 5) (at sink current 200 mA or less)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 200 mA or less
[GX-308ML(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to +V)
• Residual voltage: 2 V or less (Note 5) (at source current 200 mA or less)
 Short-circuit protectionIncorporated
Response frequency (Note 6)1,000 Hz800 Hz400 Hz100 Hz
Operation indicatorStandard I/O mode (SIO mode): Operation indicator (orange, ON), Communication indicator (green, OFF)
IO-LINK communication mode (COM mode): Operation indicator (orange, ON), Communication indicator [green, flashing (1-sec intervals)]
Pollution degree3
Altitude2,000 m 6561.68 ft or less
Environmental
resistance
ProtectionIP67 (IEC), IP69K, IP67G [IP67 (IEC), IP69K for connector type]
Ambient
temperature
-40 to +85 ℃ -40 to +185 ℉, Storage: -45 to +85 ℃ -49 to +185 ℉ (No condensation or icing allowed)
(UL temperature rating for relay connector type: -25 to +70 ℃ -13 to +158 ℉)
Ambient
humidity
35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed)
Voltage
withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration
resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock
resistance
1,000 m/s2 (GX-308ML(K)-□: 500 m/s2) acceleration in X, Y and Z directions ten times each
Sensing
range
variation
Temperature
characteristics
Within ±15% of sensing range at +23 ℃ +73 ℉ in ambient temperature range
Within ±10% of sensing range at +23 ℃ +73 ℉ in temperature range of -25 to +70 ℃ -13 to +158 ℉
Voltage
characteristics
Within ±1% for ±15 % fluctuation of the rated supply voltage
MaterialEnclosure: Nickel-plated brass [stainless steel (SUS303) for GX-308ML(K)-□],
Sensing part: Polybutylene terephthalate (PBT), Cable: Polyvinyl chloride (PVC)
Mating cable0.2 mm2 3-core oil resistant ø4 mm ø0.157 in cabtyre cable, 2 m 6.562 ft long (Note 7)0.2 mm2 3-core oil resistant ø6 mm ø0.236 in cabtyre cable, 2 m 6.562 ft long (Note 8)
WeightCable type
(Note 5)
Net weight:
55 g approx.
Gross weight:
80 g approx.
Net weight:
70 g approx.
Gross weight:
95 g approx.
Net weight:
140 g approx.
Gross weight:
170 g approx.
Net weight:
200 g approx.
Gross weight:
230 g approx.
Pigtailed typeNet weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
40 g approx.
Gross weight:
65 g approx.
Net weight:
75 g approx.
Gross weight:
100 g approx.
Net weight:
140 g approx.
Gross weight:
160 g approx.
Connector
type
-Net weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
55 g approx.
Gross weight:
80 g approx.
Net weight:
120 g approx.
Gross weight:
150 g approx.
AccessoriesNut: 2 pcs., Toothed lock washer: 1 pc.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃ +73 ℉.

2) The sensors with "N" indicated instead of □ in their model No. are NPN output type. The sensors with "P" are PNP output type.

3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

4) PNP output, normally closed type models and all NPN output models do not support IO-Link.

5) When the cable length is 2 m 6.562 ft.

6) The response frequency is an average value.

7) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø4 mm ø0.157 in cabtyre cable.

8) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø6 mm ø0.236 in cabtyre cable.

TypeNon-shielded type
Threaded type
Long sensing range
Model No.
(Note 2)
Normally openGX-308MLK-A-□GX-312MLK-A-□GX-318MLK-A-□GX-330MLK-A-□
Normally closedGX-308MLK-B-□GX-312MLK-B-□GX-318MLK-B-□GX-330MLK-B-□
Regulatory complianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Listing Certification
Max. operation distance
(Note 3)
4 mm
0.157 in ±10 %
8 mm
0.315 in ±10 %
16 mm
0.630 in ±10 %
30 mm
1.181 in ±10 %
Stable sensing range
(Note 3)
0 to 3.2 mm
0 to 0.126 in
0 to 6.4 mm
0 to 0.252 in
0 to 12.8 mm
0 to 0.504 in
0 to 24 mm
0 to 0.945 in
Standard sensing objectIron sheet
12 × 12 × t 1 mm
0.472 × 0.472 × t 0.039 in
Iron sheet
24 × 24 × t 1 mm
0.945 × 0.945 × t 0.039 in
Iron sheet
48 × 48 × t 1 mm
1.89 × 1.89 × t 0.039 in
Iron sheet
90 × 90 × t 1 mm
3.543 × 3.543 × t 0.039 in
Hysteresis15 % or less of operation distance (with standard sensing object)
Supply voltage10 to 30 V DC [including 10 % ripple (p-p)], Class 2
Current consumption16 mA or less
Output
(C/Q)
(Note 4)
IO-Link
communication
IO-Link Specification Ver1.1
Baud rateCOM3 (230.4 kbps)
Process dataPD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE2_2)
Minimum
cycle time
0.4 ms
Vendor ID834 (0x342)
Device IDGX-308□: 0x70000, GX-312□: 0x70001, GX-318□: 0x70002, GX-330□: 0x70003
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 200 mA or less
[GX-308ML(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to 0 V)
• Residual voltage: 2 V or less (Note 5) (at sink current 200 mA or less)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 200 mA or less
[GX-308ML(K)-□: 200 mA or less (-40 to +70 ℃ -40 to +158 ℉), 100 mA or less (+70 to +85 ℃ +158 to +185 ℉)]
• Applied voltage: 30 V DC or less (between output to +V)
• Residual voltage: 2 V or less (Note 5) (at source current 200 mA or less)
 Short-circuit protectionIncorporated
Response frequency (Note 6)1,000 Hz800 Hz400 Hz100 Hz
Operation indicatorStandard I/O mode (SIO mode): Operation indicator (orange, ON), Communication indicator (green, OFF)
IO-LINK communication mode (COM mode): Operation indicator (orange, ON), Communication indicator [green, flashing (1-sec intervals)]
Pollution degree3
Altitude2,000 m 6561.68 ft or less
Environmental
resistance
ProtectionIP67 (IEC), IP69K, IP67G [IP67 (IEC), IP69K for connector type]
Ambient
temperature
-40 to +85 ℃ -40 to +185 ℉, Storage: -45 to +85 ℃ -49 to +185 ℉ (No condensation or icing allowed)
(UL temperature rating for relay connector type: -25 to +70 ℃ -13 to +158 ℉)
Ambient
humidity
35 to 95 % RH, Storage: 35 to 95 % RH (No condensation allowed)
Voltage
withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
50 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration
resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock
resistance
1,000 m/s2 (GX-308ML(K)-□: 500 m/s2) acceleration in X, Y and Z directions ten times each
Sensing
range
variation
Temperature
characteristics
Within ±15% of sensing range at +23 ℃ +73 ℉ in ambient temperature range
Within ±10% of sensing range at +23 ℃ +73 ℉ in temperature range of -25 to +70 ℃ -13 to +158 ℉
Voltage
characteristics
Within ±1% for ±15 % fluctuation of the rated supply voltage
MaterialEnclosure: Nickel-plated brass [stainless steel (SUS303) for GX-308ML(K)-□],
Sensing part: Polybutylene terephthalate (PBT), Cable: Polyvinyl chloride (PVC)
Mating cable0.2 mm2 3-core oil resistant ø4 mm ø0.157 in cabtyre cable, 2 m 6.562 ft long (Note 7)0.2 mm2 3-core oil resistant ø6 mm ø0.236 in cabtyre cable, 2 m 6.562 ft long (Note 8)
WeightCable type
(Note 5)
Net weight:
55 g approx.
Gross weight:
80 g approx.
Net weight:
70 g approx.
Gross weight:
95 g approx.
Net weight:
140 g approx.
Gross weight:
170 g approx.
Net weight:
240 g approx.
Gross weight:
280 g approx.
Pigtailed typeNet weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
40 g approx.
Gross weight:
65 g approx.
Net weight:
75 g approx.
Gross weight:
100 g approx.
Net weight:
170 g approx.
Gross weight:
220 g approx.
Connector
type
-Net weight:
25 g approx.
Gross weight:
55 g approx.
Net weight:
55 g approx.
Gross weight:
80 g approx.
Net weight:
160 g approx.
Gross weight:
200 g approx.
AccessoriesNut: 2 pcs., Toothed lock washer: 1 pc.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃ +73 ℉.

2) The sensors with "N" indicated instead of □ in their model No. are NPN output type. The sensors with "P" are PNP output type.

3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

4) PNP output, normally closed type models and all NPN output models do not support IO-Link.

5) When the cable length is 2 m 6.562 ft.

6) The response frequency is an average value.

7) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø4 mm ø0.157 in cabtyre cable.

8) The bending-resistant cable type comes with a 0.2 mm2 3-core bending-resistant ø6 mm ø0.236 in cabtyre cable.

------------------------------ Tab6 showing ------------------------------

Dimensions

Unit: mm in

GX-303S-□

Sensor

GX-303S-□

GX-304S-□

Sensor

GX-304S-□

GX-305S-□

Sensor

GX-305S-□

GX-305M-□

Sensor

GX-305M-□

GX-308M(K)-□, GX-312M(K)-□, GX-318M(K)-□, GX-330M(K)-□
GX-308ML(K)-□, GX-312ML(K)-□, GX-318ML(K)-□, GX-330ML(K)-□

Sensor

Cable type / Pigtailed type

Cable type / Pigtailed type

Model No.Shielded type
ABCDEFGHIJ
GX-308M(K)M8 × 1
M8 × 0.039
37.8
1.488
4.4
0.173
26
1.024
-10
0.394
4
0.157
3
0.118
15
0.591
13
0.512
GX-312M(K)M12 × 1
M12 × 0.039
47.1
1.854
3.7
0.146
33
1.299
-12
0.472
4
0.157
4
0.157
21
0.827
17
0.669
GX-318M(K)M18 × 1
M18 × 0.039
55.3
2.177
8.5
0.335
38
1.496
-12
0.472
4
0.157
4
0.157
29
1.142
24
0.945
GX-330M(K)M30 × 1.5
M30 × 0.059
60.3
2.374
8.3
0.327
43
1.693
-12
0.472
4
0.157
5
0.197
42
1.654
36
1.417
Model No.Non-shielded type
ABCDEFGHIJ
GX-308ML(K)M8 × 1
M8 × 0.039
37.8
1.488
4.4
0.173
26
1.024
6
0.236
8
0.315
-3
0.118
15
0.591
13
0.512
GX-312ML(K)M12 × 1
M12 × 0.039
47.1
1.854
3.7
0.146
33
1.299
7
0.276
10
0.394
-4
0.157
21
0.827
17
0.669
GX-318ML(K)M18 × 1
M18 × 0.039
55.3
2.177
8.5
0.335
38
1.496
10
0.394
10
0.394
-4
0.157
29
1.142
24
0.945
GX-330MLM30 × 1.5
M30 × 0.059
60.3
2.374
8.3
0.327
43
1.693
13
0.512
10
0.394
-5
0.197
42
1.654
36
1.417
GX-330MLKM30 × 1.5
M30 × 0.059
82.3
3.240
8.3
0.327
65
2.559
15
0.591
10
0.394
-5
0.197
42
1.654
36
1.417

Connector type

直付コネクタタイプ

Model No.Shielded type
ABCDEFGHIJ
GX-312M(K)M12 × 1
M12 × 0.039
48
1.890
M12 × 1
M12 × 0.039
33
1.299
-12
0.472
4
0.157
4
0.157
21
0.827
17
0.669
GX-318M(K)M18 × 1
M18 × 0.039
53
2.087
M12 × 1
M12 × 0.039
38
1.496
-12
0.472
4
0.157
4
0.157
29
1.142
24
0.945
GX-330M(K)M30 × 1.5
M30 × 0.059
58
2.283
M12 × 1
M12 × 0.039
43
1.693
-12
0.472
4
0.157
5
0.197
42
1.654
36
1.417
Model No.Non-shielded type
ABCDEFGHIJ
GX-312ML(K)M12 × 1
M12 × 0.039
48
1.890
M12 × 1
M12 × 0.039
33
1.299
7
0.276
10
0.394
-4
0.157
21
0.827
17
0.669
GX-318ML(K)M18 × 1
M18 × 0.039
53
2.087
M12 × 1
M12 × 0.039
38
1.496
10
0.394
10
0.394
-4
0.157
29
1.142
24
0.945
GX-330MLM30 × 1.5
M30 × 0.059
58
2.283
M12 × 1
M12 × 0.039
43
1.693
13
0.512
10
0.394
-5
0.197
42
1.654
36
1.417
GX-330MLKM30 × 1.5
M30 × 0.059
80
3.150
M12 × 1
M12 × 0.039
65
2.559
15
0.591
10
0.394
-5
0.197
42
1.654
36
1.417

Note:M8 type models are not available in the connector type.

------------------------------ Tab7 showing ------------------------------

I/O Circuit and Wiring diagrams

GX-3□S-□-N
GX-305M-□-N

NPN output type

I/O circuit diagram

I/O circuit diagram

Note: Only GX-303S is 50 mA max.

Symbols

Wiring diagram

Wiring diagram

GX-3□S-□-P
GX-305M-□-P

PNP output type

I/O circuit diagram

I/O circuit diagram

Note: Only GX-303S is 50 mA max.

Symbols

Wiring diagram

Wiring diagram

GX-3□M(K)-A-N
GX-3□ML(K)-A-N

* Excluding M5 threaded type
NPN output, Normally open type

I/O circuit diagram

I/O circuit diagram

Note:In the case of the M8 threaded type:
200 mA max. (at -40 to +70 ℃ -40 to +158 ℉),
100 mA max. (at +70 to +85 ℃ +158 to +185 ℉)

Symbols

Wiring diagram

Wiring diagram

Connector pin diagram
[Pigtailed type, Connector type]

Connector pin diagram

GX-3□M(K)-B-N
GX-3□ML(K)-B-N

* Excluding M5 threaded type
NPN output, Normally closed type

I/O circuit diagram

I/O circuit diagram

Note:In the case of the M8 threaded type:
200 mA max. (at -40 to +70 ℃ -40 to +158 ℉),
100 mA max. (at +70 to +85 ℃ +158 to +185 ℉)

Symbols

Wiring diagram

Wiring diagram

Connector pin diagram
[Pigtailed type, Connector type]

Connector pin diagram

*1:that the lead color of the sensor and that of the matting cable are different.

GX-3□M(K)-A-P
GX-3□ML(K)-A-P

* Excluding M5 threaded type
PNP output, Normally open type

I/O circuit diagram

<When used as ordinary sensor>

[Standard I/O mode (SIO mode)]

I/O circuit diagram When used as ordinary sensor

Note:In the case of the M8 threaded type:
200 mA max. (at -40 to +70 ℃ -40 to +158 ℉),
100 mA max. (at +70 to +85 ℃ +158 to +185 ℉)

Symbols

<When connected to IO-Link master>
[IO-Link communication mode (COM mode)]

I/O circuit diagram When connected to IO-Link master

Notes

1):In the case of the M8 threaded type:
200 mA max. (at -40 to +70 ℃ -40 to +158 ℉),
100 mA max. (at +70 to +85 ℃ +158 to +185 ℉)

2):In the IO-Link mode, the cable between the IO‑Link master and sensor must have a length of 20 m 65.617 ft or less.

Wiring diagram

Wiring diagram

Connector pin diagram

[Pigtailed type, Connector type]

Connector pin diagram

GX-3□M(K)-B-P
GX-3□ML(K)-B-P

* Excluding M5 threaded type
PNP output, Normally closed type

I/O circuit diagram

I/O circuit diagram

Note:In the case of the M8 threaded type:
200 mA max. (at -40 to +70 ℃ -40 to +158 ℉),
100 mA max. (at +70 to +85 ℃ +158 to +185 ℉)

Symbols

Wiring diagram

Wiring diagram

Connector pin diagram

[Pigtailed type, Connector type]

Connector pin diagram

*1:that the lead color of the sensor and that of the matting cable are different.

------------------------------ Tab8 showing ------------------------------

Sensing characteristics

*TYPICAL


All models

Sensing field

Sensing field

Sensing field

Sensing field

GX-303S-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 3 × 3 × t 1 mm0.118 × 0.118 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between sensing range and repeatability

Correlation between sensing range and repeatability

GX-304S-□
GX-305M-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 4 × 4 × t 1 mm0.157 × 0.157 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between sensing range and repeatability

Correlation between sensing range and repeatability

GX-305S-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 5.4 × 5.4 × t 1 mm0.213 × 0.213 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between sensing range and repeatability

Correlation between sensing range and repeatability

GX-308M-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 8 × 8 × t 1 mm0.315 × 0.315 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-312M-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-318M-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 18 × 18 × t 1 mm0.709 × 0.709 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-330M-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-308MK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 8 × 8 × t 1 mm0.315 × 0.315 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-312MK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-318MK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 24 × 24 × t 1 mm0.945 × 0.945 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-330MK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 45 × 45 × t 1 mm1.772 × 1.772 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-308ML-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 8 × 8 × t 1 mm0.315 × 0.315 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-312ML-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 15 × 15 × t 1 mm0.591 × 0.591 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-318ML-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-330ML-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 54 × 54 × t 1 mm2.126 × 2.126 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-308MLK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-312MLK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 24 × 24 × t 1 mm0.945 × 0.945 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-318MLK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 48 × 48 × t 1 mm1.890 × 1.890 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

GX-330MLK-□

Correlation between sensing object size and sensing range

Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 90 × 90 × t 1 mm3.543 × 3.543 × t 0.039 in), the sensing range shortens as shown in the left figure.

Correlation between monitor output and sensing range

Correlation between monitor output and sensing range

------------------------------ Tab9 showing ------------------------------

Cautions For Use

  • This Web site is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use.
  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Mounting

  • The tightening torque should be under the value given below.

Installation using set screw

  • Do not tighten the product mounting nuts with excessive force.

Installation using set screw

Model No.Tightening torqueSet screw location
A (mm in)
GX-303S0.2N・m13 to 21 0.512 to 0.827
GX-304S8 to 21 0.315 to 0.827
GX-305S0.4N・m

Installation using nut

  • Do not tighten the nut with excessive force. Be sure to install the toothed locked washer.
  • In the case of the M8 threaded type, the allowable strength differs depending on the distance from the tip of the head. The following table shows the allowable tightening strengths for section B and section C shown in the diagram. (Section B starts from the tip of the head and its dimension is indicated in the table. Section C includes the nut on the head side. Therefore, if the nut extends into section B even slightly, the strength of section B is applicable.)
  • The following allowable tightening strengths are applicable when the washer is installed.

Installation using nut

Model No.
(Shielded type)
BC
Dimension
(mm in)
Tightening
torque
Tightening
torque
GX-305M-1N・m
GX-308M(K)9 0.3549N・m12N・m
GX-312M(K)-30N・m
GX-318M(K)-70N・m
GX-330M(K)-180N・m
Model No.
(Non-shielded type)
BC
Dimension
(mm in)
Tightening
torque
Tightening
torque
GX-308ML(K)3 0.1189N・m12N・m
GX-312ML(K)-30N・m
GX-318ML(K)-70N・m
GX-330ML(K)-180N・m

Mounting hole and nut dimensions

型式名D(mm in)E(mm in)
GX-303Sø3.3+0.50
ø0.130+0.01970
-
GX-304Sø4.2+0.50
ø0.165+0.01970
-
GX-305Sø5.7+0.50
ø0.224+0.01970
-
GX-305Mø5.5+0.50
ø0.217+0.01970
-
GX-308M(K)
GX-308ML(K)
ø8.5+0.50
ø0.335+0.01970
13
0.512
GX-312M(K)
GX-312ML(K)
ø12.5+0.50
ø0.492+0.01970
17
0.669
GX-318M(K)
GX-318ML(K)
ø18.5+0.50
ø0.728+0.01970
24
0.945
GX-330M(K)
GX-330ML(K)
ø30.5+0.50
ø1.201+0.01970
36
1.417

Bending radius of lead-out cable section

Bending radius of lead-out cable section

Model No.Bending radius R
GX-303S7 mm 0.276 in or more
GX-304S9 mm 0.354 in or more
GX-305S
GX-305M

Installing small-diameter sensor

  • Please use the sensor after confirming the installation distance by following (a) and (b) with an actual detection object when you install.

(a) The detection distance receives the influence by the material of the detection object, thickness, shape, and the size. So, the detection object is brought close to the front side of the sensor and detection distance (S) is measured. For the effect of the material, see the graph, "Correlation between sensing object size and sensing range".

(b) Please decide installation distance (Sa) with S × 70% or less after measuring sensing distance(S).

  • Please use the sensor after confirming the installation distance by following (a) and (b) with an actual detection object when you install.
  • Please install the sensor to come within the range of (Sa) when the detection object moves from vertical direction.
  • Please install the sensor to pass within the range of (Sa) when the detection object moves from horizontal direction.
  • When using the sensor, refer to the "Standard sensing object" specified in the specifications and the graph, "Correlation between sensing object size and sensing range".

Installing small-diameter sensor

Distance from surrounding metal

  • As metal around the sensor may affect the sensing performance, pay attention to the following points.

Influence of surrounding metal

      • The surrounding metal will affect the sensing performance. Keep the minimum distance specified in the table below.
      • When mounting the sensor using a nut, use the nut and washer provided with the product.
      • The type of the provided nut varies in different models. See the external dimensions diagrams for the detail of the shape.

Mounting method

(Unit:mm in)

Model No.
(Shielded
type)
Mounting method AMounting method B
FGHIJGKHI
GX-303S----0ø3
ø0.118
03
0.118
8
0.315
GX-304S----0ø4
ø0.157
05
0.197
10
0.394
GX-305S----0ø5.4
ø0.213
03
0.118
8
0.315
GX-305M0ø5
ø0.197
5
0.197
10
0.394
0ø5
ø0.197
05
0.197
10
0.394
GX-308M0ø8
ø0.315
4.5
0.177
12
0.472
0ø8
ø0.315
04.5
0.177
12
0.472
GX-312M0ø12
ø0.472
8
0.315
18
0.709
0ø12
ø0.472
08
0.315
18
0.709
GX-318M0ø18
ø0.709
20
0.787
27
1.063
0ø18
ø0.709
020
0.787
27
1.063
GX-330M0ø30
ø1.181
40
1.575
45
1.772
0ø30
ø1.181
040
1.575
45
1.772
GX-308MK0ø8
ø0.315
4.5
0.177
12
0.472
0ø8
ø0.315
04.5
0.177
12
0.472
GX-312MK0ø18
ø0.709
12
0.472
18
0.709
2.4
0.094
ø18
ø0.709
2.4
0.094
12
0.472
18
0.709
GX-318MK0ø27
ø1.063
24
0.945
27
1.063
3.6
0.142
ø27
ø1.063
3.6
0.142
24
0.945
27
1.063
GX-330MK0ø45
ø1.772
45
1.772
45
1.772
6
0.236
ø45
ø1.772
6
0.236
45
1.772
45
1.772
Model No.
(Non-shielded
type)
Mounting method AMounting method B
FGHIJGKHI
GX-308ML6
0.236
ø24
ø0.945
8
0.315
24
0.945
6
0.236
ø24
ø0.945
6
0.236
8
0.315
24
0.945
GX-312ML11
0.433
ø40
ø1.575
20
0.787
36
1.417
15
0.591
ø40
ø1.575
15
0.591
20
0.787
36
1.417
GX-318ML18
0.709
ø55
ø2.165
40
1.575
54
2.126
22
0.866
ø55
ø2.165
22
0.866
40
1.575
54
2.126
GX-330ML25
0.984
ø90
ø3.543
70
2.756
90
3.543
30
1.181
ø90
ø3.543
30
1.181
70
2.756
90
3.543
GX-308MLK9
0.354
ø24
ø0.945
8
0.315
24
0.945
12
0.472
ø24
ø0.945
12
0.472
8
0.315
24
0.945
GX-312MLK11
0.433
ø40
ø1.575
20
0.787
40
1.575
15
0.591
ø40
ø1.575
15
0.591
20
0.787
40
1.575
GX-318MLK21
0.827
ø70
ø2.756
48
1.890
70
2.756
25
0.984
ø70
ø2.756
25
0.984
48
1.890
70
2.756
GX-330MLK40
1.575
ø120
ø4.724
90
3.543
120
4.724
45
1.772
ø120
ø4.724
45
1.772
90
3.543
120
4.724

Mutual interference

      • When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference.

Mutual interference

Model No.
(Shielded type)
L
(mm in)
M
(mm in)
GX-303S20 0.78715 0.591
GX-304S20 0.78715 0.591
GX-305S20 0.78715 0.591
GX-305M20 0.78715 0.591
GX-308M(K)20 0.78715 0.591
GX-312M(K)30 1.18120 0.787
GX-318M50 1.96935 1.378
GX-318MK60 2.36235 1.378
GX-330M100 3.93770 2.756
GX-330MK110 4.33190 3.543
Model No.
(Non-shielded type)
L
(mm in)
M
(mm in)
GX-308ML(K)80 3.15060 2.362
GX-312ML(K)120 4.724100 3.937
GX-318ML200 7.874110 4.331
GX-318MLK200 7.874120 4.724
GX-330ML300 11.811200 7.874
GX-330MLK350 13.780300 11.811

Timing chart

Timing chart

Notes:

1)When sensors that are not compatible with IO-Link are used or when IO-Link compatible models are used as ordinary sensors, they operate in the standard I/O mode (SIO mode).

2)The operation mode can be changed by the IO-Link communications. The timer function of the output can be set up by the IO-Link communications.

Others

    • This product has been developed / produced for industrial use only.
    • Do not install the product in the following locations. Doing so may result in product failure or malfunction.
      ∙ Outdoor locations directly subject to sunlight, rain, snow, water droplets, or oil.
      ∙ Locations subject to atmospheres with chemical vapors, in particular solvents and acids.
      ∙ Locations subject to corrosive gases.
    • The product may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-frequency electric field.
    • Laying the product wiring in the same conduit or duct as high-voltage wires or power lines may result in incorrect operation and damage due to induction. Wire the product using a separate conduit or independent conduit.
    • The following conditions shall be observed if you use the product under an environment using cutting oil that may affect product’s life and/or performance.
      ∙ Usage in oil or water is prohibited.
    • Impact on the product life may differ depending on the oil you use. Before using the cutting oil, make sure that it should not cause deterioration or degradation of sealing components.
    • Never use thinner or other solvents. Otherwise, the product surface may be dissolved.
    • When turning ON the power by influence of temperature environment, an output mis-pulse sometimes occurs.
      After the product has passed for 300 ms after turning ON, please use in the stable state. If the sensing object is located near the sensor’s sensing surface, an output mis-pulse may be generated for 300 ms or longer at the time of power-on.
      Be sure to check the product for proper operation under actual operating condition before using.
    • The product is adjusted with a high degree of accuracy, so do not use in the environment with sudden temperature change.
    • Do not attempt to disassemble, repair, or modify the product.
    • Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in damage or burnout.
    • Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or burnout.
    • If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply.
    • Please use gloves to protect yourself from injury caused by screw.
    • For the connector type and pigtailed type, check the specifications of the connector cable to be used. Please do not use it under conditions that exceed the range of its specifications of both the product and the connector cable.
    • Please make sure there is no foreign matter in connector part before connecting the connector cable to the connector type and pigtailed type.
    • In the IO-Link mode, the cable between the IO-Link master and sensor must have a length of 20 m 65.617 ft or less.

MENU

Recently checked products

Recently checked product numbers