NX5-M30A-C5|Compact Multi-voltage Photoelectric Sensor NX5
Download
To Be Discontinued
Last time buy (JST)
Please note that the end date may be earlier due to various circumstances.
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | NX5-M30A-C5 |
---|---|
Part Number | NX5-M30A-C5 |
Product | Compact Multi-voltage Photoelectric Sensor |
Details | Thru-beam [Long sensing range] |
Product Name | Compact Multi-voltage Photoelectric Sensor NX5 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | NX5-M30A-C5 |
Product Number | NX5-M30A-C5 |
Products Name | Compact Multi-voltage Photoelectric Sensor |
Product details | Thru-beam [Long sensing range] |
The price of the product | Please contact our office |
Applicable regulations | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 |
Sensing range | 30 m 98.425 ft |
Sensing object | dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object) (Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected. |
Hysteresis | - |
Repeatability(perpendicular to sensing axis) | 0.2 mm 0.008 in or less |
Supply voltage | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less |
Power consumption | Emitter: 1.5 VA or less Receiver: 2 VA or less |
Output | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
Output:Output operation | Light-ON |
Response time | 10 ms or less |
Operation indicator | Red LED (lights up when the output is ON) |
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) |
Power indicator | Red LED (lights up when the power is ON) |
Sensitivity adjuster | - |
Automatic Interference prevention function | - |
Pollution degree | 3 (Industrial environment) |
Protection | IP66 (IEC) |
Ambient temperature | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage withstandability | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals |
Insulation resistance | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals |
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each |
Shock resistance | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (modulated) |
Emitting element:Peak emission wavelength | 880 nm 0.035 mil |
Material | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate |
Cable | 0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). |
Accessory | - |
Low Voltage Directive related information
Item | Specifications |
---|---|
Utilization category | AC-12/DC-12 |
Impulse withstand voltage | 2.5kV |
Output minimum operational current | DC5V 1mA or more |
Turn on time / Turn off time | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. |
Maximum response frequency | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) |
Pollution degree | 3 (Industrial environment) |
Class of protection against electric shock | Out of classification |
Excess gain | 30% |
Note | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |