Amplifier-separated Type Digital Laser Sensor LS-500
Download
-
Basic Information
-
Applications
-
Order guide
-
Option
-
Specifications
-
Dimensions
-
Circuit/ Wiring
-
Cautions For Use
------------------------------ Tab1 showing ------------------------------
Basic Information
Industry’s smallest* laser sensor head
LASER CLASS 1
CE,FDA,UKCA Approved
-
* Smallest amplifier-separated type laser sensor head as of March 2024 based on research conducted by our company
Features
Industry’s smallest* + Stainless steel (SUS) enclosure
* Amplifier-separated type laser sensor head as of March 2024, in-company survey
Stainless steel (SUS) body
Featuring stainless steel (SUS) enclosure that won't break when bumped during installation or maintenance.
One-point M6 installation
The LS-H101 features an easy-to-install design.
1 m 3.281 ft sensing range
(In STD amplifier response time mode)
Industry’s smallest* + IP67* Amplifier
*Amplifier-separated type laser sensor head as of March 2024, in-company survey
Waterproof IP67
Featuring waterproof IP67 to allow use in the presence of large amounts of water or dust.
Simple positioning
Check the optimal receiving location at a glance while watching the red spot on the beam axis adjustment screen.
1 m 3.281 ft sensing range(In STD amplifier response time mode)
The LS-H102 delivers sufficient sensing range for use with 450 mm 17.717 in wafers.
Two-point installation
The thru-beam type LS-H102 features the same form as the EX-L200 amplifier built-in ultra-compact laser sensor. And it can be used as an EX-L200 with a digital indicator.
Industry’s smallest* + Thinnest profile
*Amplifier-separated type laser sensor head as of March 2024, in-company survey
Featuring a 60% smaller design (by volume) than previous coaxial reflective models
Our smallest unit is smaller in every dimension at just W8 × H23 × D18 mm W0.315 × H0.906 × D0.709 in (excluding indicators).
Coaxial design
By using a laser with high linearity in a coaxial design, the LS-H201 is able to deliver stable sensing in confined spaces as well as simple installation.
Small, long-range spot
The LS-H201 produces a spot with a diameter of 2 mm 0.079 in at a sensing range of up to 300 mm 11.811 in (in STD amplifier response time mode).
Easy-to-see operation indicator
The LS-H201’s operation indicator is visible from all directions.
Industry’s smallest* + Horizontal symmetry
* Amplifier-separated type laser sensor head as of March 2024, in-company survey
Horizontal symmetry
Featuring a simple system design process thanks to a light source that is placed in the center of the sensor head and a coaxial design.
Industry’s smallest* and thinnest design
The LS-H901 is even thinner than previous models, measuring just W8 × H23 (excluding indicators) × D18 mm W0.315 × H0.906 × D0.709 in.
* Amplifier-separated type laser sensor head as of March 2024, in-company survey
Sensing range of 10 mm to 1 m
0.394 in to 3.281 ft
(In STD amplifier response time mode)
The LS-H901 supports close-range sensing
Among industry's fastest response times* 60 μs
* Amplifier-separated type laser sensor head as of March 2024, in-company survey
Maximum compatibility with fiber sensors
The LS-500 series features the same operation, menu displays, and form factor as the FX-500 series for increased compatibility with fiber sensors.
Detection of beam axis misalignment
Dual outputs (self-diagnosis output)
The LS-500 series can detect any reduction in incident light intensity, for example due to the accumulation of dirt such as dust, and issue an alarm. Sensing output 2 can be set as self-diagnosis output. When you teach the threshold for sensing output 1, sensing output 2 is set accordingly, allowing you to shift the threshold by a previously set margin.
Stable sensing over the long term
The LS-500’s threshold-tracking function helps maintain stable sensing over the long term and reduce maintenance man-hours. The incident light intensity can be checked and the threshold automatically reset at a user-selected interval to track changes in light intensity due to environmental changes (such as dust, etc.) over extended periods of time.
Logic operations
The LS-500’s ability to perform three logic operations (AND, OR, and XOR) on a standalone basis eliminates the need for a dedicated controller, cuts down on wiring, and lowers costs. This functionality can also be combined with the FX-500 series.
Data bank
Eight sets of amplifier settings can be stored in the unit’s built-in memory. The ability to save and load settings reduces workload when changing the setup in a multimodel production environment.
Network communication possible
Can connect to Open Network CC-Link IE Field / CC-Link / DeviceNet / EtherCAT via Communication Unit for Open Network SC-GU3 series. Monitoring and various settings can be done from PLC, PC, etc.
* CC-Link IE Field and CC-Link are trademarks of Mitsubishi Electric Corporation, and are controlled by the CC-Link Partner Association DeviceNet is a registered trademark of ODVA (Open DeviceNet Vender Association, Inc.).
EtherCAT is a registered trademark of Beckhoff Automation GmbH.
* Refer to our website for details of each sensor.
------------------------------ Tab2 showing ------------------------------
Applications
Lead frame position detectionWafer inclination detectionIC float detectionDetection of workpieces through a workbenchDetection of gaskets in capsDetection of the top of DVDs, substrate, etc.------------------------------ Tab3 showing ------------------------------
Order guide
Sensor heads
Type | Appearance | Model No. | |
---|---|---|---|
Thru-beam type | Cylindrical | LS-H101 | |
Square | LS-H102 | ||
Coaxial reflective type | LS-H201 | ||
Coaxial retroreflective type | LS-H901 |
5 m 16.404 ft cable length type
5 m 16.404 ft cable length types (Standard: 2 m 6.562 ft) are available. When ordering this type, suffix "-C5" to the model No.
Package without reflector
The LS-H901 is also available without a reflector (RF-330). When ordering this type, suffix "-Y" to the model No.
Type | Standard type Model No. | 5 m 16.404 ft cable length type | Package without reflector | |
---|---|---|---|---|
Model No. | Model No. | |||
Thru-beam type | Cylindrical | LS-H101 | LS-H101-C5 | - |
Square | LS-H102 | LS-H102-C5 | - | |
Coaxial reflective type | LS-H201 | LS-H201-C5 | - | |
Coaxial retroreflective type | LS-H901 | LS-H901-C5 | LS-H901-Y |
Amplifiers
Type | Appearance | Model No. | Output | Connection method |
---|---|---|---|---|
Connector type | LS-501 | NPN open-collector transistor two outputs | Use quick-connection cable (optional) | |
LS-501P | PNP open-collector transistor two outputs | |||
Cable type (With external input) | LS-501-C2 | NPN open-collector transistor two outputs | 2 m 6.562 ft cabtyre cable (6-core) included Cable outer diameter:ø4 mm ø0.157 in | |
LS-501P-C2 | PNP open-collector transistor two outputs |
Quick-connection cables
Quick-connection cable is not supplied with the connector type amplifier. Please order it separately.
Type | Appearance | Model No. | Description | |
---|---|---|---|---|
Main cable (4-core) | CN-74-C1 | Length: 1 m 3.281 ft | 0.2 mm2 4-core cabtyre cable, with connector on one end Cable outer diameter:ø3.3 mm ø0.130 in | |
CN-74-C2 | Length: 2 m 6.562 ft | |||
CN-74-C5 | Length: 5 m 16.404 ft | |||
Sub cable (2-core) | CN-72-C1 | Length: 1 m 3.281 ft | 0.2 mm2 2-core cabtyre cable, with connector on one end Cable outer diameter:ø3.3 mm ø0.130 in Connectable to a main cable up to 15 cables. | |
CN-72-C2 | Length: 2 m 6.562 ft | |||
CN-72-C5 | Length: 5 m 16.404 ft |
Connector
Type | Appearance | Model No. | Description |
---|---|---|---|
Connector for amplifier | CN-EP4 | Connector included with sensor head Use for maintenance, for example when another connector is damaged. Five pcs. per set |
End plates
End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.
Appearance | Model No. | Description |
---|---|---|
MS-DIN-E | When amplifiers are mounted in cascade, or when an amplifier moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. [Two pcs. per set] |
Accessories
MS-LS-1 (Sensor head mounting bracket): LS-H201□/LS-H901□
Material: Stainless steel SUS304Two M2 (length 12 mm0.472 in) screws with washers[stainless steel (SUS)] are attached.
RF-330 (Reflector)
MS-EXL2-2 (Mounting plate for thru-beam type)
Material: Stainless steel (SUS304)
------------------------------ Tab4 showing ------------------------------
Option
Designation | Model No. | Description | |
---|---|---|---|
Sensor head mounting bracket | MS-EXL2-1 | For LS-H102□ (square side sensing type) Foot angled mounting bracket | |
MS-EXL2-4 | For LS-H102□ (square side sensing type) Universal sensor mounting bracket | ||
MS-EXL2-5 | For LS-H102□ (square side sensing type) Back angled mounting bracket | ||
Amplifier mounting bracket | MS-DIN-2 | Mounting bracket for amplifier | |
Amplifier protective seal | FX-MB1 | 10 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another amplifier, as well as, prevents effect on another amplifier. Connector seal: It prevents contact of any metal, etc., with the pins of the quick-connection cable. | |
Reflector | RF-310 | For coaxial retroreflective type Compact reflector | Sensing range: 0.01 to 1m 0.033 to 3.281 ft |
Reflective tape | RF-31 | For coaxial retroreflective type Size: 9.2 × 9.2 × t 0.4 mm 0.362 × 0.362 × t 0.016 in | |
RF-33 | For coaxial retroreflective type Size: 25.2 × 27.8 × t 0.4 mm 0.992 × 1.094 × t 0.016 in | Sensing range: Same as the RF-330. |
Sensor head mounting bracket
・MS-EXL2-1
Material: Stainless steel (SUS304)Two M3 (length 14 mm0.551 in) screws with washers [stainless steel (SUS)] are attached.
・MS-EXL2-4
Material: Die-cast zinc alloyTwo M3 (length 14 mm0.551 in) screws with washers [stainless steel (SUS)], one M3 (length 10 mm0.394 in) hexagon-socket-head bolt [stainless steel (SUS)], and one M3 hexagon nut [stainless steel (SUS)] are attached.
・MS-EXL2-5
Material: Stainless steel (SUS304)Two M3 (length 14 mm0.551 in) screws with washers [stainless steel (SUS)] are attached.
Amplifier mounting bracket
・MS-DIN-2
Reflector
・RF-310
Reflective tape
・RF-33
・RF-31
Amplifier protective seal
・FX-MB1
------------------------------ Tab5 showing ------------------------------
Specifications
Sensor heads
Type | Thru-beam type | Coaxial reflective type | Coaxial retroreflective type | ||
---|---|---|---|---|---|
Cylindrical | Square | ||||
Model No. | LS-H101 | LS-H102 | LS-H201 | LS-H901 | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||||
Applicable amplifiers | LS-501(P), LS-501(P)-C2 (Note 2) | ||||
Sensing range (Note 3,4) | H-SP | 1m 3.281 ft | 1m 3.281 ft | 150mm 5.906 in | 0.01 to 1m 0.033 to 3.281 ft |
FAST | 1m 3.281 ft | 1m 3.281 ft | 200mm 7.874 in | 0.01 to 1m 0.033 to 3.281 ft | |
STD | 1m 3.281 ft | 1m 3.281 ft | 300mm 11.811 in | 0.01 to 1m 0.033 to 3.281 ft | |
LONG | 1m 3.281 ft | 1m 3.281 ft | 450mm 17.717 in | 0.01 to 1.5m 0.033 to 4.921 ft | |
U-LG | 1m 3.281 ft | 1m 3.281 ft | 600mm 23.622 in | 0.01 to 2m 0.033 to 6.562 ft | |
HYPR | 1m 3.281 ft | 1m 3.281 ft | 750mm 29.528 in | 0.01 to 2.5m 0.033 to 8.202 ft | |
Spot size | ø5 mm ø0.197 in approx. or less (at a distance from the emitter of 1 m 3.281 ft) | ø5 mm ø0.197 in approx. or less (at a distance from the emitter of 1 m 3.281 ft) | ø2 mm ø0.079 inapprox. or less (at a distance from the sensor head of 300 mm 11.811 in) | ø6 mm ø0.236 inapprox. or less (at a distance from the sensor head of 1 m 3.281 ft) | |
Sensing object | Opaque, translucent, or transparent object (Note 5) | ||||
Operation indicator | Orange LED (lights up when the amplifier output is ON) | ||||
Environmental resistance | Protection | IP40 (IEC) | IP67 (IEC) | IP40 (IEC) | IP40 (IEC) |
Ambient temperature | -10 to +55℃ + 14 to + 131 ℉ (No dew condensation or icing allowed), Storage:-20 to +70℃ -4 to +158 ℉ | ||||
Ambient humidity | 35 to 85 % RH, Storage:35 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 3,000 ℓx or less at the light-receiving face | ||||
Voltage resistance | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||||
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude or maximum acceleration 98 m/s2 in X, Y and Z directions for two hours each | ||||
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | ||||
Emitting element | Type | Red semiconductor laser diode | |||
Peak emission wavelength | 660 nm 0.026 mil | ||||
Laser class | Class 1 [IEC / EN / JIS / GB / KS / FDA (Note 6)] | ||||
Max. output | 2mW | 2mW | 2mW | 1mW | |
Material | Enclosure: Stainless steel (SUS303) Cover: Polycarbonate | Enclosure: PBT Cover: Acrylic | Enclosure: PBT, Indicator cover: Polycarbonate Beam-emitting / receiving surfaces: Glass | ||
Cable | 0.09 mm,2 2-core shielded cable, 2 m 6.562 ft long (Note 7) | 0.09 mm,2 2-core two parallel shielded cables, 2 m 6.562 ft long (Note 7) | |||
Weight | Net weight: 50 g approx. Gross weight: 75 g approx. | Net weight: 50 g approx. Gross weight: 70 g approx. | Net weight: 50 g approx. Gross weight: 80 g approx. | Net weight: 50 g approx. Gross weight: 85 g approx. | |
Accessories | M6 screw: 4 pcs. Toothed lock washer: 2 pcs. | MS-EXL2-2 (Mounting plate): 2 pcs. | MS-LS-1 (Mounting bracket): 1pc. | MS-LS-1(Mounting bracket):1pc. RF-330(Refrector): 1pc. |
Notes :
1)
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2)
When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.
3)
The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 x 100 mm 3.937 x 3.937 in) as the object.
4)The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit's receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.
5)Make sure to confirm detection with an actual sensor before use.
6)This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
7)Cable cannot be extended.
Amplifiers
Type | Connector type | Cable type | |
---|---|---|---|
Model No. | NPN output | LS-501 | LS-501-C2 |
PNP output | LS-501P | LS-501P-C2 | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||
Supply voltage | 12 to 24 V DC +10-15% Ripple P-P 10 % or less | ||
Power consumption | Normal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage,Cable type: excluding monitor current output) ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage,Cable type: excluding monitor current output) | ||
Sensing outputs (Sensing output 1, 2) (Note 4) | <NPN output type> NPN open-collector transistor ・Maximum sink current: 50 mA (Note 2) ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at max. sink current) <PNP output type> PNP open-collector transistor ・Maximum source current: 50 mA (Note 2) ・Applied voltage: 30 V DC or less (between output and +V) ・Residual voltage: 2 V or less (at max. source current) | ||
Output operation | Selectable either Light-ON or Dark-ON | ||
Short-circuit protection | Incorporated | ||
Sensing output setting | Sensing output 1 | Normal mode, differential mode, hysteresis mode, window comparator mode, selectable | |
Sensing output 2 (Note 4) | Normal mode, differential mode, hysteresis mode, self-diagnosis output mode, selectable | Normal mode, differential mode, hysteresis mode, self-diagnosis output mode, answer-back output mode, selectable | |
Response time | H-SP:60 μs or less, FAST:150 μs or less, STD:250 μs or less, LONG:500 μs or less, U-LG:5 ms or less, HYPR:24 ms or less, selectable | ||
Monitor current output | - | Output current: Approx. 4 to 20 mA (H-SP, FAST, STD: at 0 to 4,000 indication) Response time: 2 ms or less Zero point: 4 mA ± 1 % F.S. Span: 16 mA ± 5 % F.S. Linearity: ± 3 % F.S. Load resistance: 0 to 250 Ω | |
External input (Note 4) | <NPN output type> NPN non-contact input ・Signal condition High:+8 V to +V DC or open, Low:0 to +2 V DC (source current 0.5 mA or less) ・Input impedance: 10 kΩ approx. <PNP output type> PNP non-contact input ・Signal condition High:+4 V to +V DC(sink current 3.0 mA or less), Low:0 to +0.6 V DC or open ・Input impedance: 10 kΩ approx. | ||
External input function | Laser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock /display adjustment / data bank load / data bank save, selectable | ||
Sensing output operation indicator | Orange LED (lights up when sensing output 1 or sensing output 2 is ON) | ||
Laser emission indicator | Green LED (lights up during laser emission) | ||
Output select indicator | Yellow LED (lights up when output is selected) | ||
Digital display | 8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO | ||
Incident light indication range | H-SP/FAST/STD:0 to 4,000, LONG/U-LG/HYPR:0 to 9,999 | ||
Sensitivity setting | 2-point teaching / limit teaching / full auto teaching / manual adjustment | ||
Logical operation | Between sensing output 1 and calculation target: Disabled / AND / OR / XOR, selectable Calculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable | ||
Timer functions | <Sensing output 1> OFF-delay timer, ON-delay timer, One-shot timer, ON/OFF-delay timer, ON-delay / One-shot timer, switchable either effective or ineffective, with variable timer period | ||
<Sensing output 2> OFF-delay timer, ON-delay timer, One-shot timer, switchable either effective or ineffective, with variable timer period | |||
Timer period | Timer range “ms”: 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervals Timer range “sec”: 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervals Timer range “1/10 ms”: 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output. | ||
Interference prevention function | Incorporated (Note 3) | ||
Environmental resistance | Protection | IP40 (IEC) | |
Ambient temperature | -10 to +55℃ + 14 to 131 ℉ (If 4 to 7 units are mounted close together, -10 to +50 ℃ +14 to +122 ℉; if 8 to 16 units (cable type: 8 to 12 units) are mounted close together, -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | ||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||
Vibration resistance | 10 to 150 Hz frequency, 1.5 mm 0.059 in double amplitude or maximum acceleration 98 m/s2 in X, Y and Z directions for two hours each | ||
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | ||
Material | Enclosure: Polycarbonate, Cover: Polycarbonate, Switch: Polyacetal | ||
Protection | IP40(IEC) | ||
Cable | - | 0.2mm2 6-core cabtyre cable, 2 m 6.562 ft long | |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3mm2, or more, cable. | ||
Weight | Net weight: 15 g approx., Gross weight: 55 g approx. | Net weight: 75 g approx., Gross weight: 110 g approx. | |
Accessory | FX-MB1 (Amplifier protective seal): 1 set |
Notes:
1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉
2)25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).
3)Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR
4)Select either sensing output 2 or external input as the connector type.
------------------------------ Tab6 showing ------------------------------
Dimensions
- Unit: mm in
LS-H101□
Sensor head
Note: Not incorporated on the emitter.
LS-H102□
Sensor head
Note: Not incorporated on the emitter.
LS-H201□
LS-H901□
Sensor head
LS-501
LS-501P
Amplifier
LS-501-C2
LS-501P-C2
Amplifier
CN-74-C1
CN-74-C2
CN-74-C5
Main cable (Optional)
・Length (L)
Model No. | Length (mm in) |
---|---|
CN-74-C1 | 1,000 39.370 |
CN-74-C2 | 2,000 78.740 |
CN-74-C5 | 5,000 196.850 |
CN-72-C1
CN-72-C2
CN-72-C5
Sub cable (Optional)
・ Length (L)
Model No. | Length (mm in) |
---|---|
CN-72-C1 | 1,000 39.370 |
CN-72-C2 | 2,000 78.740 |
CN-72-C5 | 5,000 196.850 |
MS-DIN-E
End plate (Optional)
Material: Polycarbonate
RF-330
Reflector (Accessory for LS-H901□)
Material: Acrylic (Reflector), ABS (Base)
RF-310
Reflector (Optional)
Material: Acrylic (Reflector), ABS (Base)
RF-33
RF-31
Reflective tape (Optional)
Material: Acrylic
Model No. | A | B |
---|---|---|
RF-33 | 25.2 0.992 | 27.8 1.094 |
RF-31 | 9.2 0.362 | 9.2 0.362 |
MS-DIN-2
Amplifier mounting bracket (Optional)
Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)
MS-LS-1
Sensor head mounting bracket (Accessory for LS-H201□, LS-H901□)
Material: Stainless steel (SUS304)Two M2 (length 12 mm0.472 in) screws with washers [stainless steel (SUS)] are attached.
MS-EXL2-1
Sensor head mounting bracket for LS-H102□ (Optional)
Foot angled mounting bracket
Material: Stainless steel (SUS304)Two M3 (length 14 mm0.551 in) screws with washers [stainless steel (SUS)] are attached.
MS-EXL2-2
Mounting plate (Accessory for LS-H102□)
Material: Stainless steel (SUS304)Note: Screws are not attached. Purchase separately.
Assembly dimensions
Mounting drawing with the emitter of LS- H102□
Note: Without using the mounting plate, beam misalignment may occur.
MS-EXL2-5
Back angled mounting bracket
Material: Stainless steel (SUS304)Two M3 (length 14 mm0.551 in) screws with washers [stainless steel (SUS)] are attached.
MS-EXL2-4
Sensor head mounting bracket for LS-H102□ (Optional)
Universal sensor mounting bracket
Material: Die-cast zinc alloyTwo M3 (length 14 mm0.551 in) screws with washers [stainless steel (SUS)], one M3 (length 10 mm0.394 in) hexagon-socket-head bolt [stainless steel (SUS)], and one M3 hexagon nut [stainless steel (SUS)] are attached.
Assembly dimensions
Mounting drawing with the receiver of LS- H102□
Note: This is the adjustable range of the movable part.
------------------------------ Tab7 showing ------------------------------
I/O Circuit and Wiring diagrams
I/O circuit diagram NPN output type
Connector type
Notes:
1)The quick-connection sub cable does not have +V (brown) and 0 V (blue).The power is supplied from the connector of the main cable.
2)Wiring when sensing output 2 is selected is shown with solid lines. Wiring when external input is selected is shown with broken lines.
Cable type
*1
Symbols ...D1, D2, D3, D4: Reverse supply polarity protection diodeZD1, ZD2: Surge absorption zener diodeTr1, Tr2 : NPN output transistor
Wiring diagram
Notes:
1)The quick-connection sub cable does not have brown lead wire and blue lead wire. The power is supplied from the connector of the main cable.
2)The quick-connection cable does not have gray or pink lead wires.
Terminal layout of connector type
* Connector for amplifier (CN-EP4) pin position
Terminal No. | Connection cable |
---|---|
1 | Purple |
2 | White |
3 | Shield |
4 | Shield |
5 | Black |
6 | Pink |
I/O circuit diagram PNP output type
Connector type
Notes:
1)The quick-connection sub cable does not have +V (brown) and 0 V (blue).The power is supplied from the connector of the main cable.
2)Wiring when sensing output 2 is selected is shown with solid lines. Wiring when external input is selected is shown with broken lines.
Cable type
*1
Symbols...D1, D2, D3, D4:Reverse supply polarity protection diodeZD1, ZD2:Surge absorption zener diodeTr1, Tr2:PNP output transistor
Wiring diagram
Notes:
1)The quick-connection sub cable does not have brown lead wire and blue lead wire.The power is supplied from the connector of the main cable.
2)The quick-connection cable does not have gray or pink lead wires.
Terminal layout of connector type
* Connector for amplifier (CN-EP4) pin position
Terminal No. | Connection cable |
---|---|
1 | Purple |
2 | White |
3 | Shield |
4 | Shield |
5 | Black |
6 | Pink |
------------------------------ Tab8 showing ------------------------------
Cautions For Use
- This website is a guide to select a suitable product.
Be sure to read the instruction manual attached to the product prior to its use.
- Never use this product as a sensing device for personnel protection.
- In case of using sensing devices for personnel protection, use products which meet regulations and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
- Do not operate products using methods other than the ones described in the instruction manual included with each product. Control or adjustment through procedures other than the ones specified may cause hazardous laser radiation exposure.
Cautions for laser beams
- This product is a class 1 laser product according to IEC/EN/JIS/GB/KS standards and FDA regulations*.
- Avoid observing beams in a dark surrounding environment.
- Do not look at beams using an optical device such as an optical telephoto system.
- The following label is affixed to the emitter of this product. Handle the product according to the instruction given on the label.
This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Safety standards for laser beam products
- For the purpose of preventing any injury which may occur to the user by the use of the laser product in advance, the following standards have been established by the IEC Standards, EN Standards, JIS Standards, GB Standards, KS Standards and FDA Regulations.
IEC : IEC 60825-1:2014
EN : EN 60825-1:2014/A11:2021
JIS : JIS C 6802:2014
GB : GB 7247.1-2012
KS : KS C IEC 60825-1:2014
FDA : PART 1040.10, 1040.11(Laser Notice No.56 applied)
These standards classifies laser products according to the level of hazard and provide the safety measures for respective classes. Based on the above standards, the LS-H□ series is classified as a Class 1 laser product.
Classification | Description |
---|---|
Class 1 | Lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. |
Note: When an unexpected failure occurs, dangerous radiation may be generated. Therefore, pay special attention to safety.
Safe use of laser products
- For the purpose of preventing users from suffering injuries by laser products, each standard stipulates (Safety of laser products). Kindly check the standards before use.
Part description (Amplifier)
Mounting
Amplifier
<How to mount the amplifier>
(1)Fit the rear part of the mounting section of the amplifier on a 35 mm 1.378 in width DIN rail.
(2)Press down the rear part of the mounting section of the unit on the 35 mm 1.378 in width DIN rail and fit the front part of the mounting section to the DIN rail.
<How to remove the amplifier>
(1)Push the amplifier forward.
(2)Lift up the front part of the amplifier to remove it.
Note:Be careful. If the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break.
<How to mount the sensor head>
(1)Insert the sensor head connector into the inlet until it clicks.
(2)Fit the cover to the connector.
Sensor head:LS-H101□
- The tightening torque should be 0.98 N·m or less.
Sensor head:LS-H102□
- In case mounting this product, use a metal plate MS-EXL2-2 (accessory).
- The tightening torque should be 0.5 N·m or less with M3 screws.
- In case using the dedicated sensor head mounting bracket MS-EXL2-1 (optional) when mounting this product, the metal plate MS-EXL2-2 (accessory) is required depending on the mounting direction. Mount as the diagram below indicates.
<Not requiring the metal plate>
<Requiring the metal plate>
LS-H201□, LS-H901□
- The tightening torque should be 0.5 N・m or less.
- When placing the sensor head horizontally or vertically, the reflector must also be positioned horizontally or vertically as shown in Fig. 1 below.
If the sensor head is placed horizontally or vertically but the reflector is tilted as shown in Fig. 2 below, the reflection amount will decrease, which may cause unstable detection.
Fig. 1 Proper positioning
When placing the sensor head horizontally or vertically, the reflector shall also be positioned horizontally or vertically.
<Correct>
Fig. 2 Improper positioning
When placing the reflector tilted even when the sensor head is positioned horizontally or vertically.
<Incorrect>
Wiring
- Make sure that the power supply is off while wiring.
- Verify that the supply voltage variation is within the rating.
- Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the sensor may get burnt or damaged.
- If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
- In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
- Take care that short-circuit or wrong wiring of the load may burn or damage the sensor
- Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction.
- Ensure that an isolation transformer is utilized for the DC power supply. If an auto transformer is utilized, the main amplifier or power supply may be damaged.
- Make sure to use the optional quick-connection cable for the connection of the amplifier [connector type LS-501(P)]. Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. Set the supply voltage after considering the voltage drop caused by the cable’s resistance. When adding units, wiring length must not exceed 50 m 164.042 ft (for 5 to 8 amplifiers) or 20 m 65.617 ft (for 9 to 16 amplifiers).
Others
- Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on.
- Because the sensitivity is higher in U-LG and HYPER modes than in other modes, it can be more easily affected by extraneous noise. Check the operating environment before use.
- This sensor is suitable for indoor use only.
- Avoid dust, dirt, and steam.
- Take care that the product does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc.
- This sensor cannot be used in an environment containing inflammable or explosive gasses.
- Never disassemble or modify the sensor.