Specifications

TypeThru-beam
StandardSide view
Model No.Light-ONCY-111A□CY-111VA□
Dark-ONCY-111B□CY-111VB□
CE marking directive complianceEMC Directive, RoHS Directive
Sensing range15 m 49.213 ft
Sensing objectφ18 mm φ0.709 in or more opaque object
(Setting distance between emitter and receiver: 15 m 49.213ft)
Hysteresis-
Supply voltage12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumptionEmitter: 35 mA or less
Receiver: 35 mA or less
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 24 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less
<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 24 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less
 Utilization categoryDC-12 or DC-13
Short-circuit protectionIncorporated
Response time1 ms or less
Test input (emission halt) functionIncorporated
Operation indicatorYellow LED (lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Power indicatorGreen LED (lights up when the power is ON)
(incorporated on the emitter)
Pollution degree3 (Industrial environment)
ProtectionIP67 (IEC)
Ambient temperature–25 to +55 ℃ –13 to +131
(No dew condensation or icing allowed), Storage: –40 to +70 ℃ –22 to +158
Ambient humidity50 % RH (at +70 ℃ +158 )
Ambient illuminanceIncandescent light: 5,000 ℓx or less at the light-receiving face
Voltage withstandability500 V AC for one min. between all supply terminals connected together and enclosure
Vibration resistance10 to 55 Hz frequency, 0.5 mm 0.02 in double amplitude in X, Y and Z directions for 1.5 hours each
Shock resistance294 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Emitting elementInfrared LED (modulated)
 Peak emission wavelength890 nm 0.035 mil
MaterialEnclosure: PBT, Lens: PMMA
Cable
(except for M12 plug-in connection type)
0.44 mm2 3-core cabtyre cable, 2 m 6.562 ft long
Cable extensionExtension up to total 10 m 32.808 ft is possible with 0.34 mm2, or more, cable (thru-beam type: both emitter and receiver).
Net weight
(Note 5)
2 m cable length typeEmitter/Receiver: 65 g approx.Emitter/Receiver: 70 g approx.
M12 plug-in connector typeEmitter/Receiver: 15 g approx.Emitter/Receiver: 20 g approx.
AccessoriesNut: 4 pcs.
TypeRetroreflective
 With polarizing filters
StandardSide viewStandardSide view
Model No.Light-ONCY-192A□CY-192VA□CY-191A□CY-191VA□
Dark-ONCY-192B□CY-192VB□CY-191B□CY-191VB□
CE marking directive complianceEMC Directive, RoHS Directive
Sensing range4 m 13.123 ft (Note 2)2 m 6.562 ft (Note 2)
Sensing objectφ50 mm φ1.969 in or more opaque, translucent or transparent object (Note 2, 4)φ50 mm φ1.969 in or more opaque, translucent, transparent or specular object (Note 2, 4)
Hysteresis-
Supply voltage12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption35 mA or less
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 24 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less
<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 24 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less
 Utilization categoryDC-12 or DC-13
Short-circuit protectionIncorporated
Response time1 ms or less
Test input (emission halt) function-
Operation indicatorYellow LED (lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Power indicator-
Pollution degree3 (Industrial environment)
ProtectionIP67 (IEC)
Ambient temperature–25 to +55 ℃ –13 to +131
(No dew condensation or icing allowed), Storage: –40 to +70 ℃ –22 to +158
Ambient humidity50 % RH (at +70 ℃ +158 )
Ambient illuminanceIncandescent light: 5,000 ℓx or less at the light-receiving face
EMCEN 60947-5-2
Voltage withstandability500 V AC for one min. between all supply terminals connected together and enclosure
Vibration resistance10 to 55 Hz frequency, 0.5 mm 0.020 in double amplitude in X, Y and Z directions for 1.5 hours each
Shock resistance294 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Emitting elementInfrared LED (modulated)Red LED (modulated)
 Peak emission wavelength875 nm 0.034 mil665 nm 0.026 mil
MaterialEnclosure: PBT, Lens: PMMA
Cable
(except for M12 plug-in connection type)
0.44 mm2 3-core cabtyre cable, 2 m 6.562 ft long
Cable extensionExtension up to total 10 m 32.808 ft is possible with 0.34 mm2, or more, cable (thru-beam type: both emitter and receiver).
Net weight
(Note 5)
2 m cable length type65 g approx.70 g approx.65 g approx.70 g approx.
M12 plug-in connector type15 g approx.20 g approx.15 g approx.20 g approx.
AccessoriesNut: 2 pcs.
TypeDiffuse reflective
 With sensitivity adjuster
StandardSide viewStandardSide view
Model No.Light-ONCY-121A□CY-121VA□CY-122A□CY-122VA□
Dark-ONCY-121B□CY-121VB□CY-122B□CY-122VB□
CE marking directive complianceEMC Directive, RoHS Directive
Sensing range100 mm 3.937 in (Note 3)600 mm 23.622 in (Note 3)
Sensing objectOpaque, translucent or transparent object
(Note 4)
Hysteresis3 to 15 % of operation distance (Note 3)
Supply voltage12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption35 mA or less
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 24 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less
<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 24 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less
 Utilization categoryDC-12 or DC-13
Short-circuit protectionIncorporated
Response time1 ms or less
Test input (emission halt) function-
Operation indicatorYellow LED (lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Power indicator-
Pollution degree3 (Industrial environment)
ProtectionIP67 (IEC)
Ambient temperature–25 to +55 ℃ –13 to +131
(No dew condensation or icing allowed), Storage: –40 to +70 ℃ –22 to +158
Ambient humidity50 % RH (at +70 ℃ +158 )
Ambient illuminanceIncandescent light: 5,000 ℓx or less at the light-receiving face
EMCEN 60947-5-2
Voltage withstandability500 V AC for one min. between all supply terminals connected together and enclosure
Vibration resistance10 to 55 Hz frequency, 0.5 mm 0.020 in double amplitude in X, Y and Z directions for 1.5 hours each
Shock resistance294 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Emitting elementInfrared LED (modulated)
 Peak emission wavelength875 nm 0.034 mil
MaterialEnclosure: PBT, Lens: PMMA
Cable
(except for M12 plug-in connection type)
0.44 mm2 3-core cabtyre cable, 2 m 6.562 ft long
Cable extensionExtension up to total 10 m 32.808 ft is possible with 0.34 mm2, or more, cable (thru-beam type: both emitter and receiver).
Net weight
(Note 5)
2 m cable length type65 g approx.70 g approx.75 g approx.
M12 plug-in connector type15 g approx.20 g approx.25 g approx.
AccessoriesNut: 2 pcs.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 .
2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-420 reflector (optional).
3) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
4) Make sure to confirm detection with an actual sensor before use for detection of the transparent object and the translucent object.
5) The weight includes the weight of nuts.

 

------------------------------ Tab3 showing ------------------------------

Dimensions

  • Unit: mm in

CY-1□

Sensor

pic01

 
 
 2 m cable length type (mm in)M12 plug-in connector type (mm in)
abab
Standard type CY-111□/121□/192□46 1.81128 1.10260 2.36228 1.102
Standard type CY-191□48 1.89028 1.10262 2.44128 1.102
Side view type CY-111V□/121V□/191V□/192V□62 2.44128 1.10276 2.99228 1.102
Standard type CY-122□62 2.44144 1.73276 2.99244 1.732
Side view type CY-122V□78 3.07144 1.73292 3.62244 1.732

CN-24C-C2
CN-24C-C5

Mating cable

pic02

 

CN-24CL-C2
CN-24CL-C5

Mating cablepic03

MS-CY1-1

Sensing mounting bracket

 pic04

MS-CY1-2

Sensing mounting bracket

 pic05

MS-AJ3

Universal sensor mounting stand

1. Ball-joint mounted fixing bracket CY-100 series or RF-420

pic06


2. M12 rod
 pic07
 
3. Support for M12 rod
 pic08
 

RF-420

Reflector

 pic09

RF-410

Reflector

 pic10

------------------------------ Tab4 showing ------------------------------

I/O Circuit and Wiring diagrams

Wiring diagram

 

Emitter of thru-beam type

pic01

Receiver of thru-beam / Reflective type

NPN output type

pic02

Receiver of thru-beam / Reflective type
PNP output type

pic03

Connector pin position

M12 connector

pic04

1:+V
2:Input (Only emitter of thru-beam type)
3:0 V
4:(Only receiver of thru-beam type and reflective type)

 

------------------------------ Tab5 showing ------------------------------

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Mounting

  • The tightening torque should be 3 N·m or less.
  • Use a cable with connector CN-24C(L)-C□ (optional) for M12 connector type.
    Tightening torque for connector part is 2 N·m or less.

pic01

Mounting drawing with sensor or reflector RF-420

pic02

Wiring

  • Make sure that the power supply is off while wiring.
  • Verify that the supply voltage variation is within the rating.
  • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
  • Ensure that an isolation transformer is utilized for the DC power supply.
    If an autotransformer is utilized, the main body or power supply may be damaged.
  • If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge.
  • Do not use during the initial transient time (0.5 sec) after the power supply is switched on.
  • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
  • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway.
    This can cause malfunction due to induction.
  • Damage or burnout may result in case of short circuit of load or miswiring.
  • Make a cable length as short as possible to lessen noise pickup.

Others

  • This device has been developed / produced for industrial use only.
  • Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance.
  • Avoid using a product where there is excessive vapor, dust or corrosive gas,
    or in a place where it could be exposed directly to water or chemicals.
  • Take care that the sensor does not come in direct contact with water, oil, grease or organic solvents,
    such as, thinner, etc.
  • Do not use in an environment containing infammable or explosive gases.
  • Never disassemble or modify the product.

MENU

Recently checked products

Recently checked product numbers