DC supply type

TypeThru-beamRetrorefl ectiveDiffuse refl ective
 With polarizing filters
Model No.NPN outputCY-21CY-27CY-29CY-22
PNP outputCY-21-PNCY-27-PNCY-29-PNCY-22-PN
Sensing range12 m 39.370 ft3 m 9.843 ft
(Note 2)
1.5 m 4.921 ft
(Note 2)
120 mm 4.724 in (Note 3)
Sensing objectø8 mm ø0.315 in or more
opaque object
(Completely beam interrupted object)
ø50 mm ø1.969 in or more
opaque or translucent object
(Note 2, 4)
ø50 mm ø1.969 in or more opaque,
translucent or specular object
(Note 2, 4)
Opaque, translucent or
transparent object (Note 4)
Hysteresis-15 % or less of operation
distance (Note 3)
Repeatability
(perpendicular to sensing axis)
0.1 mm 0.004 in or less0.3 mm 0.012 in or less
Supply voltage10 to 30 V DC Ripple P-P 10 % or less
Current consumptionEmitter: 20 mA or less
Receiver: 25 mA or less
25 mA or less
Output<NPN output type>
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between output and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current)
<PNP output type>
PNP open-collector transistor
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less (between output and +V)
・Residual voltage: 1.5 V or less (at 100 mA source current)
 Utilization categoryDC-12 or DC-13
Output operationSelectable either Light-ON or Dark-ON by the control input
Short-circuit protectionIncorporated
Response time2 ms or less
Test input (emission halt) functionIncorporated-
Operation indicatorRed LED (lights up when the output is ON)
Emission indicatorRed LED
(lights up during
beam emission)
-
Pollution degree3 (Industrial environment)
ProtectionIP67 (IEC) (Refer to p.984 for details of standards.)
Ambient temperature-25 to +55 ℃ -13 to +131 ℉
(No dew condensation or icing allowed),
Storage: -30 to +70 ℃ -22 to +158 ℉
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminanceIncandescent light: 3,000 lx at the light-receiving face
EMCEN 60947-5-2
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting elementInfrared LED (modulated)Red LED (modulated)Infrared LED (modulated)
 Peak emission wavelength950 nm 0.037 mil660 nm 0.026 mil950 nm 0.037 mil
MaterialEnclosure: PBT, Lens: PolycarbonateEnclosure: PBT, Front cover: Acrylic
Cable0.34 mm2 4-core (thru-beam type emitter: 3-core) cabtyre cable, 2 m 6.562 ft long
Cable extensionExtension up to total 100 m 328.084 ft is possible with 0.34 mm2, or more, cable (thru-beam type: both emitter and receiver).
Net WeightEmitter: 90 g approx.
Receiver: 100 g approx.
100 g approx.
AccessoriesNut: 4 pcs.Nut: 2 pcs.

Note 1 :Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

Note 2 :The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector (optional).

Note 3 :The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.

Note 4 :Make sure to confirm detection with an actual sensor before use.

AC supply type

TypeThru-beamRetroreflectiveDiffuse reflective
 With polarizing filters
Model No.Light-ONCY-11ACY-17ACY-19ACY-12A
Dark-ONCY-11BCY-17BCY-19BCY-12B
Sensing range12 m 39.370 ft3 m 9.843 ft
(Note 2)
1.5 m 4.921 ft
(Note 2)
120 mm 4.724 in (Note 3)
Sensing objectø8 mm ø0.315 in or more opaque object
(Completely beam interrupted object)
ø50 mm ø1.969 in or more opaque or translucent object
(Note 2, 4)
ø50 mm ø1.969 in or more opaque, translucent or specular object (Note 2, 4)Opaque, translucent or transparent object (Note 4)
Hysteresis-15 % or less of operation
distance (Note 3)
Repeatability
(perpendicular to sensing axis)
0.1 mm 0.004 in or less0.3 mm 0.012 in or less
Supply voltage24 to 240 V AC + 10/- 15 %
Power consumptionEmitter: 1.5 VA or less
Receiver: 2.5 VA or less
2.7 VA or less
OutputAC non-contact (thyristor) output
・Load current: 5 to 200 mA
・Applied voltage: 24 to 240 V AC + 10/- 15 %
・Residual voltage: 4 V or less (at 200 mA load current)
Response time20 ms or less
Operation indicatorRed LED (lights up when the output is ON),
incorporated on the receiver for the thru-beam type sensor
Power indicatorRed LED
(lights up when the power
is ON), incorporated on the emitter
-
Pollution degree3 (Industrial environment)
ProtectionIP67 (IEC) (Refer to p.984 for details of standards.)
Ambient temperature-25 to +55 ℃ -13 to +131 ℉
(No dew condensation or icing allowed),
Storage: -30 to +70 ℃ -22 to +158 ℉
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminanceIncandescent light: 3,000 lx at the light-receiving face
EMCEN 61000-6-2, EN 61000-6-4
Voltage withstandability1,500 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting elementInfrared LED (modulated)Red LED (modulated)Infrared LED (modulated)
 Peak emission wavelength950 nm 0.037 mil660 nm 0.026 mil950 nm 0.037 mil
MaterialEnclosure: PBT, Lens: PolycarbonateEnclosure: PBT, Front cover: Acrylic
Cable0.34 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Cable extensionExtension up to total 100 m 328.084 ft is possible with 0.34 mm2, or more, cable (thru-beam type: both emitter and receiver).
Net weightEmitter: 90 g approx.
Receiver: 100 g approx.
100 g approx.
AccessoriesNut: 4 pcs.Nut: 2 pcs.

Note 1 :Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

Note 1 :The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector (optional).

Note 1 :The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.

Note 1 :Make sure to confirm detection with an actual sensor before use.

------------------------------ Tab3 showing ------------------------------

Dimensions

  • Unit: mm in

CY-21□ CY-22□ CY-27□

Sensor

CY-21□ CY-22□ CY-27□

Note:It is the emitting indicator (red) on the emitter of the thru-beam type sensor.

CY-21□-J CY-22□-J CY-27□-J

Sensor

CY-21□-J CY-22□-J CY-27□-J

Note:It is the emitting indicator (red) on the emitter of the thru-beam type sensor.

CY-29□

Sensor

CY-29□

CY-29□-J

Sensor

CY-29□-J

CY-11□ CY-12□ CY-17□

Sensor

CY-11□ CY-12□ CY-17□

Note:It is the power indicator (red) on the emitter of the thru-beam type sensor.

CY-11□-J CY-12□-J CY-17□-J

Sensor

CY-11□-J CY-12□-J CY-17□-J

Note:It is the power indicator (red) on the emitter of the thru-beam type sensor.

CY-19□

Sensor

CY-19□

CY-19□-J

Sensor

CY-19□-J

MENU

Recently checked products

Recently checked product numbers