Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

Ultra-small U-shaped Micro Photoelectric Sensor[Amplifier Built-in] PM-24 (Discontinued Products)

  • Discontinued Products

  • Specifications

  • Dimensions

  • Circuit/ Wiring

  • Sensing characteristics

  • Cautions For Use

Ⅾiscontinued

Last time buy (JST)

March 31, 2017

We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.

------------------------------ Tab1 showing ------------------------------

Discontinued Products

pic01

------------------------------ Tab2 showing ------------------------------

Specifications

TypeUltra-small
 With flexible cable
Model No.NPN outputPM-□24PM-□24-R
PNP outputPM-□24P-
Sensing range5 mm 0.197 in (fixed)
Minimum sensing object0.8 x 1.8 mm 0.031 x 0.071 in opaque object
Hysteresis0.05 mm 0.002 in or less
Repeatability0.03 mm 0.001 in or less
Supply voltage5 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption15 mA or less
Output<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 0.7 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)

<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (between output and + V)
• Residual voltage: 0.7 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
 Utilization categoryDC-12 or DC-13
Output operationIncorporated with 2 outputs: Light-ON / Dark-ON
Response timeUnder light received condition: 20 µs or less
Under light interrupted condition: 100 µs or less
(Response frequency: 1 kHz or more) (Note 2)
Operation indicatorVermilion LED (lights up under light received condition)
Pollution degree3 (Industrial environment)
Ambient temperature
(Note 3, 4)
–25 to +55 ℃ –13 to +131 (No dew condensation or icing allowed),
Storage: –30 to +80 ℃ –22 to +176
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminanceFluorescent light: 1,000 ℓx at the light-receiving face
EMCEN 60947-5-2
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each
Emitting elementInfrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated)
MaterialEnclosure: PBT, Slit cover: Polycarbonate
Cable0.09 mm2 4-core cabtyre cable [PM-□24-R: 0.1 mm2 flexible, oil and heat resistant cabtyre cable (Note 5)], 1 m 3.281 ft long
Cable extensionExtension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
WeightNet weight: 10 g approx.

Notes:

1)  Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

2)  The response frequency is the value when the disc, given in the figure below, is rotated.

3)  In case the PM-24 series is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body.

4)  Take care that the flexibility of the PM-□24-R cable is lost if the ambient temperature in –10 ℃ +14 ℉ or less.

5)  The cable of PM-□24-R is a flexible cable usable on a moving base. When the sensor is mounted on a moving base, fix the sensor cable joint so that stress is not applied to it. (Models other than the PM-□24-R cannot be used on a moving base.)

------------------------------ Tab3 showing ------------------------------

Dimensions

  • Unit: mm in

PM-K24(P)
PM-K24-R

Sensor

PM-K24(P) PM-K24-R

PM-L24(P)
PM-L24-R

Sensor

PM-L24(P) PM-L24-R

PM-F24(P)
PM-F24-R

Sensor

PM-F24(P) PM-F24-R

PM-R24(P)
PM-R24-R

Sensor

PM-R24(P) PM-R24-R

PM-U24(P)
PM-U24-R

Sensor

PM-U24(P) PM-U24-R

------------------------------ Tab4 showing ------------------------------

I/O Circuit and Wiring diagrams

PM-□24
PM-□24-R

NPN output type

I/O circuit diagram

I/O circuit diagram

Notes:1)Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit.Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage.2)Ensure to insulate the unused output wire.

Wiring diagram

Wiring diagram

Output operation

 Color codeOutput operation
Output 1BlackLight-ON
Output 2WhiteDark-ON

PM-□24P

PNP output type

I/O circuit diagram

I/O circuit diagram

Notes:1)Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit.Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage.2)Ensure to insulate the unused output wire.

Wiring diagram

Wiring diagram

Output operation

 Color codeOutput operation
Output 1BlackLight-ON
Output 2WhiteDark-ON

------------------------------ Tab5 showing ------------------------------

Sensing characteristics

(TYPICAL)

Sensing position

------------------------------ Tab6 showing ------------------------------

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
  • Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit.
    Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage.

Mounting

  • When fixing the sensor with screws, use M2 screws and the tightening torque should be 0.15 N·m or less.
    Further, use small, round type plain washers. (ø4.3 mm ø0.169 in)
    When using the optional mounting screw set MS-M2, a spring washer is included.

Mounting

  • In case the PM-24 series is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body.

Cable extension

  • Cable extension is possible up to an overall length of 100 m 328.084 ft with a 0.3 mm2, or more, cable.
    However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the cable attached to the sensor is within the rating.

Cable extension

But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage.

Conductor cross section
area of
extension cable
Total cable length
0.08 to 0.1 mm2Up to 5 m 16.404 ft
0.2 mm2Up to 10 m 32.808 ft
0.3 mm2Up to 20 m 65.617 ft

Others

  • Since the sensor is intended for use inside machines, no special countermeasures have been taken against extraneous light. Take care that extraneous light is not directly incident on the beam receiving section.

  • Do not use during the initial transient time (50 ms) after the power supply is switched on.
  • The cable of PM-□24-R is a flexible cable usable on a moving base. When the sensor is mounted on a moving base, fix the sensor cable joint so that stress is not applied to it. (Models other than the PM-□24-R cannot be used on a moving base.)
  • Take care that the flexibility of the PM-□24-R cable is lost if the ambient temperature is -10℃ +14 ℉ or less.