This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | SC-GU2-C |
---|---|
Part Number | SC-GU2-C |
Product | Communication Unit for CC-Link |
Product Name | Communication Unit for CC-Link SC-GU2-C |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | SC-GU2-C |
Product Number | SC-GU2-C |
Products Name | Communication Unit for CC-Link |
The price of the product | Please contact our office |
Applicable sensor amplifier | Sensor amplifiers (NPN output type) that can connect to non-line connector CN-70 (optional) (FX-500/300/311/410 series, LS-401/403, DPS-401/402, GA-311) (Note) Only the below models respond to data communication. FX-501/502, LS-403, DPS-401/402 |
Number of units connectable | Max. 16 units (Sensor amplifiers / input units) (Maximum of 12 units including the FX-500 Series can communicate optically) |
Supply voltage | 24 V DC +10-15 % Ripple P-P 10 % or less |
Current consumption | 110 mA or less (excluding connected sensor amplifiers / input units) |
Allowable passing current | Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2) (Note 1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. (Note 2) In case of supplying power to other devices, be sure to set the current less than allowable passing current. |
Communication method | CC-Link Ver.1.10 |
Number of occupied station | Switchable 1 or 4 station |
Communication speed / Total extension length | 10 Mbps / 100 m 328.084 ft 5 Mbps / 150 m 492.126 ft 2.5 Mbps / 200 m 656.168 ft 625 kbps / 600 m 1968.504 ft 156 kbps / 1,200 m 3937.008 ft |
Communication cable | Specified cable (twist pair cable with shield) (Note) Use the CC-Link-specified cable. |
Station No. setting | 1 to 64 (0 and 65 or more: Error) |
Remote station type | Remote device station |
Ambient temperature | -10 to +55 degrees +14 to +131 degrees Fahrenheit (If 4 to 7 units are connected in cascade: -10 to +50 degrees +14 to +122 degrees Fahrenheit , if 8 to 16 units are connected in cascade: -10 to +45 degrees +14 to +113 degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Heat-resistant ABS Connector cap: Silicone rubber |
Weight | Net weight: 60 g approx. Gross weight: 100 g approx. |
Accessory | Connector cap: 2 pcs. |