NA2-N12|General Purpose & Slim Body Area Sensor NA2-N
Download
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | NA2-N12 |
---|---|
Part Number | NA2-N12 |
Product | General Purpose & Slim Body Area Sensor |
Details | NPN output |
Product Name | General Purpose & Slim Body Area Sensor NA2-N |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | NA2-N12 |
Product Number | NA2-N12 |
Products Name | General Purpose & Slim Body Area Sensor |
Product details | NPN output |
The price of the product | Please contact our office |
Sensing height | 220 mm 8.661 in |
Sensing range | 5 m 16.404 ft |
Beam pitch | 20 mm 0.787 in |
Sensing object | dia. 30 mm dia. 1.181 in or more opaque object (completely beam interrupted objects) |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Power consumption:Emitter:Job indicator ON | 0.8 W or less |
Power consumption:Emitter:Job indicator OFF | 0.7 W or less |
Power consumption:Receiver:Job indicator ON | 0.8 W or less |
Power consumption:Receiver:Job indicator OFF | 0.7 W or less |
Output | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) |
Output:Utilization category | DC-12 or DC-13 |
Output:Output operation | ON when all beam channels are received (OFF when one or more beam channels are interrupted) |
Output:Short-circuit protection | Incorporated |
Response time | 10 ms or less (12 ms or less when the interference prevention function is used) |
Indicators:Emitter | Emitting indicator: Green LED x 2 (light up during emission; one LED lights up for Frequency A setting, both LEDs light up for Frequency B setting) Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch) |
Indicators:Receiver | Operation indicator: Red LED (lights up when one or more beam channels are interrupted) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch) * When an excess current flows through the output, the stable incident beam indicator and the operation indicator on the receiver blink simultaneously due to operation of the short-circuit protection circuit. |
Interference prevention function | Incorporated |
Test input (emission halt) function | Incorporated |
Pollution degree | 3 (Industrial environment) |
Protection | IP40(IEC) |
Ambient temperature | -10 to +55 degrees +14 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -10 to +60 degrees +14 to +140 degrees Fahrenheit |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil, modulated) (Note:Peak emission wavelength has been changed from production in March, 2017.) |
Material | Enclosure: Heat-resistant ABS Lens cover: Polyester Indicator cover: Acrylic |
Cable | 0.2 mm2 4-core cabtyre cable, 3 m 9.843 ft long |
Cable extension | Extension up to total 25 m 82.021 ft is possible for both emitter and receiver, with 0.2 mm2, or more, cable. |
Weight(Total weight of emitter and receiver) | Net weight: 400 g approx. Gross weight: 600 g approx. |