Sensing height | 220mm | 300mm | 380mm |
---|
Sensing range | 5m |
---|
Beam pitch | 20mm |
---|
Sensing object | ø30mm or more opaque object |
---|
Supply voltage | 12 to 24V DC510% Ripple P-P 10% or less |
---|
Power consumption (Note) | Emitter: 0.5W or less (0.4W or less when job indicator is off) Receiver: 0.8W or less (0.7W or less when job indicator is off) | Emitter: 0.5W or less (0.4W or less when job indicator is off) Receiver: 0.9W or less (0.8W or less when job indicator is off) | Emitter: 0.5W or less (0.4W or less when job indicator is off) Receiver: 1.0W or less (0.9W or less when job indicator is off) |
---|
Output | NPN open-collector transistor ・Maximum sink current: 100mA ・Applied voltage: 30V DC or less (between output and 0V) ・Residual voltage: 1V or less (at 100mA sink current) 0.4V or less (at 16mA sink current) |
---|
| Output operation | ON when all beams are received (OFF when one or more beams are interrupted) |
---|
Short-circuit protection | Incorporated |
---|
Indicators | Emitter | Power indicator: Green LED x 2(light up when the power is ON; emission frequency (a) or (b) is indicated by the number of LEDs lighting up) Job indicator: Red LED (lights up, blinks, or lights off when the job indicator input is at Low; lighting pattern is selected by operation mode switch) |
---|
Receiver | Operation indicator: Red LED (lights up when one or more beams are interrupted, and blinks alternately with the stable incident beam indicator when an abnormal condition is found out by the test-run) Stable incident beam indicator: Green LED (lights up when all beams are stably received, and blinks alternately with the operation indicator when an abnormal condition is found out by the test-run) Job indicator: Red LED (lights up, blinks, or lights off when the job indicator input is at Low; lighting pattern is selected by operation mode switch) * When an excess current flows through the output, the stable incident beam indicator and the operation indicator on the receiver blink simultaneously due to the operation of the short-circuit protection circuit. |
---|
Interference prevention function | Incorporated |
---|
Test-run function | Incorporated |
---|
Environmental resistance | Ambient temperature | -10 to +55 ℃ (No dew condensation or icing allowed), Storage: -10 to 60 ℃ |
---|
Ambient humidity | 35 to 85% RH, Storage: 35 to 85% RH |
---|
Ambient illuminance | Sunlight: 10,000lx at the light-receiving face, Incandescent light: 3,000lx at the light-receiving face |
---|
Noise immunity | Power line: 240Vp, 10ms cycle, and 0.5μs pulse width Radiation: 300Vp, 10ms cycle, and 0.5μs pulse width (with noise simulator) |
---|
Voltage withstandability | 1,000V AC for one min. between all supply terminals connected together and enclosure |
---|
Insulation resistance | 20M½, or more, with 250V DC megger between all supply terminals connected together and enclosure |
---|
Vibration resistance | 10 to 150Hz frequency, 0.75mm amplitude in X, Y and Z directions for two hours each |
---|
Shock resistance | 490m/s2 acceleration (50G approx.) in X, Y and Z directions for three times each |
---|
Emitting element | Infrared LED (modulated) |
---|
Material | Enclosure: Heat-resistant ABS, Lens cover: Polyester, Indicator cover: Acrylic |
---|
Cable | 0.2mm2 4-core cabtyre cable, 3m long |
---|
Cable extension | Extension up to total 25m is possible for both emitter and receiver, with 0.2m2, or more, cable. |
---|
Weight | 400g approx. | 450g approx. | 500g approx. |
---|