1) General Specifications

ItemDescription
Rated operating voltage24 V DC
Operating voltage range21.6 to 26.4 V DC
Allowable momentary power off timeAllowable momentary power off time 3 ms (3 to 10 ms is restored after the allowable momentary power off operation. *1)
Ambient temperature0 to +55 ℃
Storage temperature-20 to +70 ℃
Ambient humidity30 to 85 % RH (at 25 ℃ non-condensing)
Storage humidity30 to 85 % RH (at 25 ℃ non-condensing)
Breakdown voltageBetween "input terminal" and "power/ground terminals":
500 V AC *2 for 1 minute
Between "output terminal" and "power/ground terminals":
1500 V AC *2 for 1 minute
Between "input terminal" and "output terminal": 1500 V AC *2 for 1 minute
Insulation resistanceBetween "input terminal" and "power/ground terminals":
Over 100 MΩ(at 500 V DC with megohmmeter)
Between "output terminal" and "power/ground terminals":
Over 100 MΩ(at 500 V DC with megohmmeter)
Between "input terminal" and "output terminal": Over 100 MΩ(at 500 V DC with megohmmeter)
Vibration resistance10 to 55 Hz, 1 sweep/min.,
Double amplitude of 0.75 mm, 10 min. on 3 axes (Towards X,Y & Z directions)
Shock resistance98 m/s2 or more, 4 times on 3 axes (Towards X,Y & Z directions)
Noise immunity1000 V[P-P] with pulse width 50 ns, 1μs (using a noise simulator)
Operating conditionMust be free from corrosive gasses and excessive dust
Current Consumption (at 24 V DC)Web Datalogger Unit (DLU) : 300 mA or less
Communication cassette COM1, COM2 : 20 mA or less *3
Communication cassette COM3, COM4 : 25 mA or less *3
WeightApprox. 200 g

*1 Momentary power cut is recorded in the system history.
*2 Cut-off current: 10 mA, excluding the varistor for protection.
*3 Add this value on the consumption current of Web Datalogger Unit.

Function Specifications

1) Function specifications

ItemSpecifications
Data loggingData sampling I/FInternal I/OInput: 4 points (Pulse input 30 Hz or less)/Output: 1 point
Expansion unit (Up to 3 units can be connected.)Digital system:  Input: 48 points (Pulse input 1 Hz or less)/Output: 48 points Analog system:  Input 24 CH/Output 24 CH
Through communication cassette- FP-series PLC(Eco-power meter, wireless sensor)
- Mitsubishi FX series
- Mitsubishi FX2N series
- Mitsubishi FX-series computer link
- Omron SYSMAC-C series
Logging dataDescription- Contact system:  Select from "Instantaneous value (ON/OFF)", "Accumulated ON time", "Total switching times" and "Pulse value". - Register system:  Instantaneous value, average value, minimum value, maximum value, difference value
Data format (Available in register system)16-bit integer (Signed/Unsigned), 32-bit integer (Signed/Unsigned) Binary (16 bits/32 bits), HEX (16 bits/32 bits), character string, real number
No. of registerable files16
Registerable device *1Total 4000 points (250 points/1 file)
Data saveStorage place *2- Internal memory (SDRAM):  2M bytes
- CF card:  8M to 1G bytes
File systemVFAT/FAT/FAT32
Saving formatCSV
TriggerTrigger type- Fixed cycle (Select from the cycles predefined, which are 1 second to 24 hours.)
- Relay (Leading edge differential, trailing edge differential, both edge differential)
- Appointed time (Specify the date and time for every day, etc)
- Register (=, >, <, ≠)
No. of registerable triggers128
OthersMail Transmission functionTransmission networkLAN, PPP (dial-up)
Mail contentsMail title: Within 16 characters
Mail text Within 254 characters
No. of registerable settings64
Data setting functionSet objectDLU output, expansion unit (output), PLC/eco-power meter, etc.
No. of registerable settings64
Monitor functionStandard screenBuilt-in standard monitor screen (using a web browser) *3
Network functionCommunication protocolTCP/IP, UDP/IP, PPP (Client/Server)
Application protocolHTTP, SMTP(POP/APOP authentication), FTP(server), SNTP, DHCP
Clendar timerAt 0 °C less than 119 seconds per month, at 25 °C less than 51 seconds per month, at 55 °C less than 148 seconds per month
(The automatic correction using the SNTP is available.)
BackupLogging data *4, calendar timer
(By a gold capacitor and a backup battery sold separately)
Battery discharge life (Value applies when no power is supplied at all) *4250 days or more (Typical lifetime in actual use: approx. 5 years (at 25℃)) (Suggested replacement interval: 1 year)
Security functionUser name, password, account type (2 levels)
Self-diagnostic FunctionWatchdog timer, setting value check, battery voltage drop

*1 The registerable numbers are 16 files, 250 in total. Registering 4000 points is available by setting consecutive points (1 to 250) for one registration.
*2 The data in the internal memory will be deleted when the power turns off. (It cannot be backed up with a battery.
Use the memory as an area for temporarily generating csv files.
*3 The web browser used should be Internet Explorer 6.0 or later.
*4 It is the discharge life after turning on electricity to the power supply of DLU for over 5 hours. The battery life is influenced by the environments such as temperature.

------------------------------ Tab3 showing ------------------------------

Dimensions

  • Unit: mm in

AFL1200

MENU

Recently checked products

Recently checked product numbers