ASFP84371|DC Fan Motor 80 x 25t(ASFP8)(Discontinued)
Download
Discontinued
Last time buy (JST)
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Spec Detail
| Item | Specifications |
|---|---|
| Part Number | ASFP84371 |
| Product Number | ASFP84371 |
| Products Name | DC Fan Motor |
| Product details | Low speed |
RATING
| Item | Specifications |
|---|---|
| Rated voltage | 12 V |
| Input power | max 0.72 W AVE 0.60 W |
| Rated current | max 60 mA AVE 50 mA |
| Rotation speed | min 1,800 min-1 AVE 2,000 min-1 |
| Max. air flow | min 0.65 m3/min AVE 0.74 m3/min |
| Max. static pressure | min 12.5 Pa AVE 16.5 Pa |
| Noise | max 24.0 dB AVE 19.0 dB |
| Weight | 80 g |
SPECIFICATIONS
| Item | Specifications |
|---|---|
| Ambient temperature | -10℃ to +60℃ +14℉ to +140℉ |
| Humidity resistance test condition | 85 ℃ 185 ℉, 95% RH, 240 hrs. |
| Temperature rise | Coil surface: Max. 50℃ 122℉ (Nominal voltage, by resistive method) Exterior:Max. 20℃ 68℉ (Nominal voltage, by thermocouple method) |
| Breakdown voltage | 500 V AC for 1 min. (between lead wire and external housing) |
| Insulation resistance | Min. 10 MΩ (at 500 V DC) |
| Vibration resistance:Frequency | 10 to 55Hz |
| Vibration resistance:Double amplitude width | 0.75mm |
| Vibration resistance:Applied direction | X, Y and Z directions |
| Vibration resistance:Applied time | 10 min. in each direction |
| Lead wire tensile strength | 9.8 N, single wires did not break at 15 seconds |
| Fan blockage | No coil burnout even after blockage of 72 hrs. at nominal voltage. |
| Reverse polarity power connection | No damage even after reverse polarity connection for short time at nominal voltage. |
| Expected life | 40,000 hours at 60 ℃ (Life time when continuously energized by applying the rated voltage Current value: + 15% or more Rotation speed: -15% or less) |