| Product Number | AEV18012 |
|---|---|
| Part Number | AEV18012 |
| Product | Normal type |
| Details | 1 Form A |
| FAQ | Not Recommended for New Design |
| Product Name | EV Relays (DC Contactors) |
| Features | High voltage DC, High capacity Cut-off Relays using Capsule Contact Mechanism |
The external content (including but not limited to ECAD data) displayed hereafter is provided solely as reference data for design evaluation and review purposes. We make no warranties whatsoever with respect to such content, including, without limitation, its accuracy, completeness, usefulness, reliability, fitness for a particular purpose, non-infringement of intellectual property rights or other rights of any third party, or any other matter. In particular, please note that the content displayed hereafter may be presented after being simplified or converted by a third party based on data originally provided by us.
To the maximum extent permitted by applicable law, any use, editing, or any design, evaluation, manufacture, or other activities based on such content shall be undertaken solely at your own risk and responsibility. We shall not be liable for any damages, losses, or expenses arising from or in connection with any of the foregoing, whether in contract, tort (including negligence), strict liability, or otherwise.
Content provided by third parties may be subject to terms and conditions established by such third parties.
If you have read and agree to the above, please click "OK".
- Download RoHS Compliance Certificate
- Download EU REACH SVHC Report
- A List of Part Numbers in This Series
Contact Us
Spec Detail
| Item | Specifications |
|---|---|
| Part Number | AEV18012 |
| Product Number | AEV18012 |
| Products Name | Normal type |
| Product details | 1 Form A |
| FAQ | Not Recommended for New Design |
| Protective construction | Capsule contact |
| Terminal shape | Screw terminal |
| Coil terminal structure | Connector |
| Operating function | Single side stable |
| Rated coil voltage | 12V DC |
| Operate (Set) voltage (at20℃) (Initial) | Max. 9V DC |
| Release (Reset) voltage (at20℃) (Initial) | Min. 1V DC |
| Rated operating current [±10%] (at 20℃) | 0.353 A |
| Coil resistance [±10%] (at 20℃) | 34Ω |
| Rated operating power (at 20℃) | 4.2W |
| Usable voltage range | 10 to 16V DC |
| Contact arrangement | 1 Form A |
| Contact capacity | 80 A |
| Contact material | Tungsten and copper alloys |
| Rated switching capacity (resistive) | 80A 450V DC (Carry, 15mm2 wire) |
| Max. carring current | 80A Continuity 120A 15 min. 180A 20 min. (15mm2 wire) |
| Min. switching load (resistive) | 1A 12V DC (at 20℃) |
| Contact voltage drop (initial) | Max. 0.067V (By Voltage drop 6V DC 20A) |
| Insulated resistance (Initial) | Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) |
| Dielectric strength (Between open contacts) (Initial) | 2,500 Vrms for 1min. (detection current: 10mA.) |
| Dielectric strength (Between contacts and coil) (Initial) | 2,500 Vrms for 1min. (detection current: 10mA.) |
| Operate (Set) time (at rated coil voltage) (at 20℃) (Initial) | Max. 50ms (without bounce) |
| Release (Reset) time (at rated coil voltage) (at 20℃) (Initial) | Max. 30ms (with no coil protective elements) |
| Shock resistance: Functional | For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
| Shock resistance: Destructive | Min. 490 m/s2 (half-sine shock pulse: 6 ms) |
| Vibration resistance: Functional | 10 to 200 Hz, 43 m/s2 (detection time: 10 μs) |
| Vibration resistance: Destructive | 10 to 200 Hz, 43 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours) |
| Expected life: Mechanical life | Min. 2 x 105 |
| Expected life: Electrical life (resistive) | 80A 450V DC, Min. 1,000 operations |
| Expected life: Switch-off life | [Forward direction]: 800A 300V DC, Min. 1 operation 120A 450V DC, Min. 50 operations [Reverse direction]: -120A 200V DC, Min. 50 operations |
| Expected life: Inrush current (capacitor) | 150A 20V DC, Min. 70,000 operations |
| Conditions | Ambient temperature: –40 to +80℃, Humidity: 5 to 85% RH (Avoid icing when using at temperatures lower than 0℃.) |
| Unit weight | Approx. 400 g |
| Inner carton (pieces) | 1 |
| Outer carton (pieces) | 20 |