HG-SC111|接觸式數位位移感測器 HG-S
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
| 品名 | HG-SC111 |
|---|---|
| 型號 | HG-SC111 |
| 產品 | Contact-Type Digital Displacement Sensor |
| 詳細 | Slave unit High-performance type |
| 商品名稱 | 接觸式數位位移感測器 HG-S |
※為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
詳細規格
為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
| 項目 | 內容 |
|---|---|
| 品名 | HG-SC111 |
| 型號 | HG-SC111 |
| 產品名 | Contact-Type Digital Displacement Sensor |
| 適合規制 | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| 汚損度 | 2 |
| 使用標高 | 2000 m 6561.68 ft or less |
| 耐環境性能: 保護構造 | IP40 (IEC) |
| Environmental resistance : Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉' |
| Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Environmental resistance : Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each |
| Environmental resistance : Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
| 材質 | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| 重量 | Net weight: 140 g approx. |
| 備註 | Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉. |
| External inputs (Input 1, Input 2, Input 3):Trigger input | Input time 2 ms or more (ON) |
Controller
| 項目 | 內容 |
|---|---|
| Compatible sensor head | HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050 |
| Number of connectable units | Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| Analog current output | • Current output range:4 to 20 mA/F.S.(default value) • Error output:0 mA • Linearity:±0.25% F.S. • Load impedance:250Ω max. |
| Control outputs(Output 1, Output 2, Output 3) | NPN open-collector transistor • Maximum sink current: 50 mA(Note 5)) • Applied voltage: 30 V DC or less(between output and 0 V) • Residual voltage: 1.5 V or less(at 50 mA sink current) • Leakage current: 0.1 mA or less PNP open-collector transistor • Maximum source current: 50 mA(Note 5) • Applied voltage: 30 V DC or less(between output and +V) • Residual voltage: 1.5 V or less(at 50 mA source current) • Leakage current: 0.1 mA or less |
| Control outputs(Output 1, Output 2, Output 3):Short-circuit protection | Incorporated (automatic reset type) |
| Control outputs(Output 1, Output 2, Output 3):Judgment output | NO / NC switching method |
| Control outputs(Output 1, Output 2, Output 3):Alarm output | Open when alarm occurs |
| External inputs (Input 1, Input 2, Input 3) | Non-contact input or NPN open-collector transistor • Input condition: Invalid (+8 V to +V DC or open) Valid (0 to +1.2 V DC) •Input impedance: 10 kΩ approx. Non-contact input or PNP open-collector transistor • Input condition: Invalid (0 to +0.6 V DC or open) Valid (+4 V to +V DC) • Input impedance: 10 kΩ approx. |
| External inputs (Input 1, Input 2, Input 3):Preset input | Input time 20 ms or more (ON) |
| External inputs (Input 1, Input 2, Input 3):Reset input | Input time 20 ms or more (ON) |
| External inputs (Input 1, Input 2, Input 3) Bank input A / B | Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B. |
| Response time | 3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type |
| Digital display | 204-segment LCD |
| Display resolution | 0.1μm 0.004 mil |
| Display range | -199.9999 to 199.9999mm -7.874 to 7.874 in |
| Contamination level | 2 |
| Elevation | 2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Environmental resistance:Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Cable | 0.15 mm2, 7‑core composite cable, 2 m 6.562 ft long |
| Notes | Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉. |
Controllers
| 項目 | 內容 |
|---|---|
| Supply voltage | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Current consumption | 70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output. |