GP-XC5SE|高速·高精度渦電流型數位位移感測器 GP-X
※ 實際商品可能與照片不同。
適合不含有規定:EU RoHS指令 2011/65/EU的6物質、以及EU RoHS指令2015/863/EU的4物質
| 品名 | GP-XC5SE |
|---|---|
| 型號 | GP-XC5SE |
| 產品 | High Speed High Accuracy Eddy Current Type Digital Displacement Sensor |
| 詳細 | Non-threaded type sensor head + Controller |
| 商品名稱 | 高速·高精度渦電流型數位位移感測器 GP-X |
※為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
詳細規格
為了商品改進,規格和外觀可能會在不事先通知的情況下變更,敬請諒解。
| 項目 | 內容 |
|---|---|
| 品名 | GP-XC5SE |
| 型號 | GP-XC5SE |
| 產品名 | High Speed High Accuracy Eddy Current Type Digital Displacement Sensor |
| 顯示價格 | Please contact our office |
Controllers
| 項目 | 內容 |
|---|---|
| Type | NPN output |
| Supply voltage | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Current consumption | 150 mA or less |
| Resolution | 0.04 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . |
| Sampling frequency | 40 kHz (25 micro s) |
| Linearity | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . |
| Temperature characteristics | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and controller. |
| Analog voltage outputs | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) |
| Analog voltage outputs : Response time | 75 micro s (maximum speed) |
| Comparative outputs (HI, GO, LO) | NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and 0 V) -Residual voltage: 1.6 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Comparative outputs (HI, GO, LO) : Utilization category | DC-12 or DC-13 |
| Comparative outputs (HI, GO, LO) : Output number | HI / GO / LO 3 value output |
| Comparative outputs (HI, GO, LO) : Output operation | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value |
| Comparative outputs (HI, GO, LO) : Short-circuit protection | Incorporated |
| External input | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between +24 V and input), OFF voltage 4 V or less (between +24 V and input) - Input impedance: 5 kΩ approx. |
| Serial I/O | RS-232C |
| Zero-set setting method | Push button setting / External input setting |
| Indicators : MODE | Orange LED (lights up when in mode status) |
| Indicators : HI | Orange LED (lights up when the upper limit value is exceeded) |
| Indicators : GO | Green LED (lights up when within the upper and lower limit value) |
| Indicators : LO | Orange LED (lights up when less than the lower limit value) |
| Indicators : TIMING | Green LED (lights up as per the external or internal trigger timing) |
| Upper level digital display part | 5 digit orange LED (display of numerical values out of upper and lower limit value) |
| Lower level digital display part | 5 digit green LED (display of numerical values within the upper and lower limit value) |
| Pollution degree | 3 (Industrial environment) |
| Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: 0 to +50 ℃ +32 to +122 ℉ |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
| Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
| Material | Enclosure: Polycarbonate |
| Weight | Net weight: 120 g approx. |
| Accessory | ATA4811 (Controller mounting frame): 1 set |
Sensor heads
| 項目 | 內容 |
|---|---|
| Type | Non-threaded type For 1 mm 0.039 in sensing |
| Sensing range | 0 to 1 mm 0 to 0.039 in (Note) The sensing range is specified for the standard sensing object. |
| Standard sensing object | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in |
| Temperature characteristics | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. |
| Pollution degree | 3 (Industrial environment) |
| Protection | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) |
| Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Voltage withstandability | 250 V AC for one min. between all supply terminals connected together and enclosure |
| Insulation resistance | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each |
| Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each |
| Enclosure | Stainless steel (SUS303) |
| Cable protector | PP |
| Sensing part | PAR |
| Cable | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. |
| Cable extension | Extension up to total 10 m 32.808 ft is possible with the optional cable. |
| Net Weight | 40 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| Accessories | - |