ER-VW|Thin-type Ionizer ER-VW
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | ER-VW |
---|---|
Part Number | ER-VW |
Product | Thin-type Ionizer |
Details | Spot type |
Product Name | Thin-type Ionizer ER-VW |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | ER-VW |
Product Number | ER-VW |
Products Name | Thin-type Ionizer |
Product details | Spot type |
The price of the product | Please contact our office |
Charge removal time | 1 sec. or less (plus or minus1,000 V to plus or minus100 V) (Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
Ion balance | plus or minus10 V or less (Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
Ozone generation | 0.05 ppm or less (Note) A typical sample applied with a supply voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. |
Applicable fluid | Air (dried clean air) (Note) Dry clean air is air that has been processed through an air dryer (freezing point around –20 ℃ –4 ℉) and an air filter (mesh size around 0.01 microm 0.0004 mil). |
Supplied air flow | 60 liter/min. (ANR) or less |
Air pressure range | 0.05 to 0.5 MPa |
Supply voltage | 24 V DC plus or minus 10 % |
Current consumption | 120 mA or less |
Discharge method | High frequency AC method |
Discharge output voltage | 2,000 V approx. |
Output [Check (CHECK) Error (ERROR) Discharge (DSC)] | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) (Note:"DSC" is an abbreviated name of "DISCHARGE".) |
Output:Output operation | Check output (CHECK): ON when the discharge needle is dirty or worn, OFF when operation is normal Error output (ERROR): OFF when abnormal discharge is detected, ON when operation is normal Discharge output (DSC) (Note): ON when discharging, OFF when discharge halts (Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’. |
Output:Short-circuit protection | Incorporated |
Discharge halt input (DSC OFF) | Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start) (Note:"DSC" is an abbreviated name of "DISCHARGE".) |
Reset input (RESET) | In the state that operation is stopped due to an error detection, open 0 V of the power supply from short-circuit state to cancel ERROR |
Indicators:Power (POWER) | Green LED (lights up when the power is ON) |
Indicators:Discharge (DSC) | Green LED (lights up when discharging) (Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’. |
Indicators:Air monitoring (AIR) | Orange LED (lights up when no air is being supplied) (Note) Discharge halts when lights up. |
Indicators:Check (CHECK) | Orange LED (lights up when the discharge needle is dirty or worn, etc.) |
Indicators:Error (ERROR) | Red LED (lights up when abnormal discharge is detected) |
Ambient temperature | 0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed), Storage: –10 to +65 ℃ +14 to +149 ℉ |
Ambient humidity | 35 to 65 % RH (No dew condensation allowed), Storage: 35 to 65 % RH |
I/O connector | For power & input / output: 8-pin connector, For connection: 9-pin connector |
Connectable units | Maximum number of connectable units: 5 (Including this unit) |
Enclosure earthing | Capacitor earth |
Material | Enclosure: ABS (Nickel plated), Nozzle mount, Screw mount, Nozzle: Stainless steel. Discharge needle: Tungsten |
Weight | Net weight: 110 g approx., Gross weight: 180 g approx. |
Accessories | Connector attached cable: 1 pc. (length 0.5 m 1.640 ft), End connector (9-pin): 1 pc., Lead wire for connecting F.G.: 1 pc. |