DP-102ZL3-M-P|Dual Display Digital Pressure Sensor [For Gas] DP-100L
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | DP-102ZL3-M-P |
---|---|
Part Number | DP-102ZL3-M-P |
Product | Dual Display Digital Pressure Sensor [For Gas] |
Details | Discrete wire type |
Product Name | Dual Display Digital Pressure Sensor [For Gas] DP-100L |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | DP-102ZL3-M-P |
Product Number | DP-102ZL3-M-P |
Products Name | Dual Display Digital Pressure Sensor [For Gas] |
Product details | Discrete wire type |
Regulatory compliance and certification | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification |
Type of pressure | Gauge pressure |
Rated pressure range | -0.100 to +1.000 Mpa |
Set pressure range | -0.101 to +1.010MPa |
Pressure withstandability | 1.5MPa |
Applicable fluid | Non-corrosive gas |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
Power consumption | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage) 360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) |
Communication output (C/Q):IO-Link communication | IO-Link Specification V1.1 (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Communication output (C/Q):Baud rate | COM3 (230.4 kbps) (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Communication output (C/Q):Process data | 4 byte (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Communication output (C/Q):Minimum cycle time | 1.0ms (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Control output (DO) | PNP open-collector transistor •Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 2 V or less (at 50 mA source current) |
Control output (DO):Output operation | N.O./N.C. (selectable by key operation) |
Control output (DO):Output operationOutput modes | EASY mode / Hysteresis mode / Window comparator mode |
Control output (DO):Hysteresis | Minimum 1 digit (variable) |
Control output (DO):Repeatability | ±0.2 % F.S. (within ±2 digits) |
Control output (DO):Response time | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
Control output (DO):Short-circuit protection | Incorporated |
Display | 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
Display:Displayable pressure range | -0.101 to +1.010MPa |
Output indicator | Orange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2) Output operation indicator 2: Lights up when the control output is ON) |
Protection | IP40(IEC) |
Ambient temperature | -10 to +50℃ +14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃ +14 to +140 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Temperature characteristics | Within ±1 % F.S. (at +20℃ +68℉) |
Pressure port | M5 female thread |
Material | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber |
Connecting method | Connector |
Cable length | Total length up to 20 m 65.617 ft (Condition of CE compliance less than 20 m 65.617 ft) is possible with 0.3 mm2, or more, cable. |
Weight | Net weight: 30 g approx., Gross weight: 125 g approx. |
Accessories | CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc. |
Remark | (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. |