SC-HG1-ETC|Communication Unit for Digital Displacement Sensors SC-HG1
Download

*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
Product Number | SC-HG1-ETC |
---|---|
Part Number | SC-HG1-ETC |
Product | EtherCAT communication unit |
Product Name | Communication Unit for Digital Displacement Sensors SC-HG1 |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Part Number | SC-HG1-ETC |
Product Number | SC-HG1-ETC |
Products Name | EtherCAT communication unit |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Compatible controllers | HG-TC□, HG-SC□ |
Maximum number of connectable controllers | Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-ETC unit |
Supply voltage | 24 V DC ±10 %, including ripple 0.5 V (P-P) (Note) : Power is supplied from a connected controller / master controller. |
Current consumption | 100 mA or less |
Communication protocol | EtherCAT |
Compliance | IEEE 802.3u (100BASE-TX) |
Communication speed | 100 Mbps (100BASE-TX) |
Communication connector | RJ-45×2 |
Node-to-node distance | 100 m 328.084 ft or less |
Supported functions | Process data object communication (cyclic communication) Mailbox communication (message communication) CoE Explicit Device Identification Station Alias |
Degree of pollution | 2 |
Operating altitude | 2,000 m 6,561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
Environmental resistance : Ambient temperature | -10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ or higher, using 250 V DC megger between all supply terminals connected together and enclosure |
Environmental resistance : Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each |
Environmental resistance : Shock resistance | 98 m/s2 (10 G approx.) acceleration in X, Y, and Z directions five times each |
Grounding method | Casing: Floating type |
Material | Enclosure : Polycarbonate |
Communication cable | Category 5e (shielded twisted pair cable recommended) |
Weight | Net weight: 90 g approx. Gross weight: 150 g appox. |